![Dell EMC VMAX Configuration And Best Practices Technical Notes Download Page 36](http://html1.mh-extra.com/html/dell-emc/vmax/vmax_configuration-and-best-practices-technical-notes_2468344036.webp)
36
The revert operation may take some time to run. As the revert is running, the host will discover that the paths to the source array are
active again. This is monitored by the VMAX, which will wait for the rediscovery before proceeding.
C:\>symdm cancel -sid 0129 -sg lcseb246_sg -revert -nop
A DM 'Cancel Revert' operation is
in progress for storage group 'lcseb246_sg'. Please wait...
Analyze Configuration..........................................Started.
Source SID:000195703184
Target SID:000197800129
Analyze Configuration..........................................Done.
Revert Data Replication........................................Started.
Revert Data Replication........................................In Progress.
Revert Data Replication........................................Done.
Remove Masking View(s) on Target...............................Started.
Remove Masking View(s) on Target...............................In Progress.
Remove Masking View(s) on Target...............................Done.
Remove Data Replication........................................Started.
Remove Data Replication........................................Done.
Remove Port Group(s) on Target.................................Started.
Remove Port Group(s) on Target.................................Done.
Remove Initiator Group(s) on Target............................Started
Remove Initiator Group(s) on Target............................Done.
Remove Duplicate Device(s) on Target...........................Started.
Wait for deallocation to complete..............................Started.
Wait for deallocation to complete..............................Done.
Remove Duplicate Device(s) on Target...........................In Progress.
Remove Duplicate Device(s) on Target...........................Done.
Remove Storage Group(s) on Target..............................Started.
Remove Storage Group(s) on Target..............................Done.
The DM 'Cancel Revert' operation successfully executed for
storage group 'lcseb246_sg'.
After a revert operation, the state of the devices and the systems are the same as they were prior to the create operation.
Note: Following the cancel -revert operation, the host paths to the target array are no longer available. The paths to
the source array should be returned to the original configuration to avoid Data Unavailability. A host HBA rescan should
be undertaken to ensure application stability. Note: The revert operation may take some time to complete. The “Revert
Data Replication” step will repeat and remain “In Progress” until the step is complete. However the application will
immediately be reverted back to operating on the source array. The length of the revert task is based around the time
the target array takes to deallocate the target devices and clean up after the cancelled migration.
Summary of Contents for VMAX
Page 6: ...6 Figure 1 NDM Overview ...
Page 60: ...60 Click the angle bracket next to Add to Job List and click Run Now ...
Page 65: ...65 Source device ...
Page 72: ...72 Source Device ...
Page 73: ...73 Target Device ...
Page 75: ...75 Click the angle bracket next to Add to Job List and click Run Now ...