Figure 44. Installing intrusion switch
2
Slide the intrusion switch until it is firmly seated in the intrusion switch slot.
3
Connect the intrusion switch cable to the connector on the system board.
Next steps
1
Installing the internal PERC riser
2
Follow the procedure listed in
After working inside your system
.
Drives
Removing a drive blank
The procedure for removing 2.5-inch and 3.5-inch drive blanks is identical.
Prerequisites
1
Follow the safety guidelines listed in
2
If installed,
CAUTION:
To maintain proper system cooling, drive blanks must be installed in all empty drive slots.
CAUTION:
Mixing drive blanks from previous generations of PowerEdge servers is not supported.
Step
Press the release button, and slide the drive blank out of the drive slot.