Thermal restriction matrix
Table 33. Thermal restriction matrix for R540
Storage configuration
Front
8 drive
12 drive
12 drive
Rear
NA
NA
2 drive
Fan type
Standard fan
Standard fan
High
performance fan
CPU heat sink type
1.5U heat sink
1.5U heat sink
1U heat sink
Processor
number
TDP (W)
Core count
Ambient = 35°C
Ambient = 35°C
Ambient = 30°C
Ambient = 30°C
Intel Xenon Gold
6138
125
20
Yes
Yes
Yes
Yes
Intel Xenon Gold
6130
125
16
Yes
Yes
Yes
Yes
Intel Xenon Gold
6126
125
12
Yes
Yes
Yes
Yes
Intel Xenon Gold
6128
115
6
Yes
No
Yes
Yes
Intel Xenon Gold
5122
105
4
Yes
No
Yes
Yes
Intel Xenon Gold
5115
85
10
Yes
Yes
Yes
Yes
Intel Xenon Silver
4116
85
12
Yes
Yes
Yes
Yes
Intel Xenon Silver
4114
85
10
Yes
Yes
Yes
Yes
Intel Xenon Silver
4110
85
8
Yes
Yes
Yes
Yes
Intel Xenon
Bronze 3106
85
8
Yes
Yes
Yes
Yes
Intel Xenon
Bronze 3104
85
6
Yes
Yes
Yes
Yes
Intel Xenon Silver
4112
85
4
Yes
Yes
Yes
Yes
Particulate and gaseous contamination specifications
The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If
the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to
rectify the environmental conditions. Re-mediation of environmental conditions is the responsibility of the customer.
40
Technical specifications