![Dell EMC DP5300 Field Replacement Manual Download Page 35](http://html1.mh-extra.com/html/dell-emc/dp5300/dp5300_field-replacement-manual_2468355035.webp)
Procedure
1. In the IDPA vCenter Server, select Hosts and Clusters
>
DPappliance-VSAN.
2. Select Manage
>
Settings
>
Virtual SAN
>
General.
3. Select Edit, and change the Add disks to storage value to Manual.
Note
There are two Edit buttons on the screen. Use the top button that is located
across from
Virtual SAN is Turned ON
.
4. Select OK.
5. Select Manage
>
Settings
>
Virtual SAN
>
Disk Management.
6. Using the information that was previously gathered, select the disk group that
contained the failed SSD, and select the failed SSD from the list. Select All
Actions. From the pulldown menu, select Remove Disks from Group.
7. Click Remove.
8. Select No data Migration.
9. Click Yes, and allow some time for the removal operation to complete. Check
the progress of the removal operation in the Recent Tasks pane at the bottom
of the screen.
CAUTION
Removing the SSD destroys the vSAN group.
Dell PowerEdge R630 Server FRUs
DELL EMC CONFIDENTIAL
Prepare a failed SSD for replacement
35