DLS 300 / 450 / 600
61
Code 240.010.0001
PV System with battery storage
DLS-300 (300 L)
DLS-450
DLS-600
Ambient Conditions
Ambient temperature
-20°C…+60°C
-20°C…+60°C
-20°C…+60°C
Power derating temperature range
40°C…+60°C
40°C…+60°C
40°C…+60°C
Storage temperature
-30°C…+70°C
-30°C…+70°C
-30°C…+70°C
Relative humidity
5%...95% without conden-
sation
5%...95% without conden-
sation
5%...95% without conden-
sation
Noise levels
< 50 dB(A) @ 1m
< 50 dB(A) @ 1m
< 50 dB(A) @ 1m
Maximum operating altitude without derating
2000m
2000m
2000m
Pollution degree classification
PD 3
PD 3
PD 3
Installation environmental category
Indoors without air condi-
tioning
Indoors without air condi-
tioning
Indoors without air condi-
tioning
Physical
Protection rating
IP 21
IP 21
IP 21
Overvoltage category (IEC 62109-1)
II (DC, BATTERY, GEN-
ERATOR inputs)
III (AC inputs and outputs)
II (DC, BATTERY, GEN-
ERATOR inputs)
III (AC inputs and outputs)
II (DC, BATTERY, GEN-
ERATOR inputs)
III (AC inputs and outputs)
Ventilation
I-cool
I-cool
I-cool
Dimensions (W x H x D) in mm
710 x 650 x 150
710 x 650 x 150
710 x 650 x 150
Weight
< 30 Kg
< 30 kg
< 30 kg
Fitting system
Wall bracket
Wall bracket
Wall bracket
Safety
Protection class
I
I
I
DC to AC isolation level
Without transformer
Without transformer
Without transformer
BATTERY to AC and DC isolation level
With safety transformer
With safety transformer
With safety transformer
Certifications
CE
CE
CE
EMC and Safety standards
EN62109-1; EN62109-2;
EN61000-6-2; EN61000-
6-3; EN61000-3-2;
EN61000-3-3; EN61000-3-
11; EN61000-3-12
EN62109-1; EN62109-2;
EN61000-6-2; EN61000-
6-3; EN61000-3-2;
EN61000-3-3; EN61000-3-
11; EN61000-3-12
EN62109-1; EN62109-2;
EN61000-6-2; EN61000-
6-3; EN61000-3-2;
EN61000-3-3; EN61000-3-
11; EN61000-3-12
Mains connection standards
CEI 0-21
CEI 0-21
CEI 0-21
Other Features
BACKUP/OFF-GRID mode operation
Yes, with built-in interlock
Yes, with built-in interlock
Yes, with built-in interlock
ON-GRID/BACKUP/OFF-GRID selection mode
Yes, automatic
Yes, automatic
Yes, automatic
Grid support (grid services)
Yes, if required by the
standard
Yes, if required by the
standard
Yes, if required by the
standard
Input for auxiliary power generator
Optional
Optional
Optional
Residential loads management
Yes, with home automation
PCB (optional)
Yes, with home automation
PCB (optional)
Yes, with home automation
PCB (optional)
Auxiliary power generator remote control
Yes, with home automation
PCB (optional)
Yes, with home automation
PCB (optional)
Yes, with home automation
PCB (optional)
(*) The specified range may vary according to the mains connection standard enforced in the country of installation