Diagnostics: Dell PowerVault 124T DLT VS160 Autoloader User's Guide
file:///T|/htdocs/stor-sys/124T/en/124tvs16/diag.html[12/5/2012 10:26:06 AM]
Diagnostics: Dell™ PowerVault™ 124T DLT VS160 Autoloader
User's Guide
Diagnostic Tests from the Front Panel
Remote Management Unit Diagnostic Tests
Diagnostic Tests from the Front Panel
Diagnostic tests allow you to calibrate parts of the autoloader, check the condition of parts, or test the autoloader's
functionality. From the front panel, you can perform all of the diagnostic tests. Because certain tests require you to manually
insert a minimum of 2 cartridges, you can perform only some of the diagnostic tests using the Remote Management Unit (see
"
Remote Management Unit Diagnostic Tests
NOTE:
The Remote Management Unit allows you to request all diagnostic tests, but any tests that require a cartridge to
be inserted will time-out unless someone manually inserts the cartridge at the appropriate time.
Setting the Security
When you enable the security function, the diagnostic tests are password protected to ensure data integrity. To access any of
the diagnostic tests, you must first enter an Administrator password. If you do not enter the password, you will be prompted
to enter the password when you attempt to perform a diagnostic test.
You can also enter passwords from the Command menu as follows:
1. From any menu, click the
Commands
heading. The
Commands
screen displays.
2. On the
Commands
submenu, scroll to
Enter Password
, and then press
Enter
.
3. On the
Enter Password
submenu, scroll to
Administrator
, and then press
Enter
.
4. In the text box, scroll to the first number of the password, and then press
Enter
.
5. Repeat step 4 to enter the remaining numbers of your password.
NOTE:
Press
Escape
to backspace to a previous text box, if necessary.
When you have finished entering your password,
Submit Password
appears on the LCD below the asterisks.
6. Press
Enter
to submit your password. The display returns to the
Enter Password
submenu.
Stopping a Diagnostic Test
At times, you may need to stop a diagnostic test while it is in progress. To stop a diagnostic test while it is running, use the
End Curr. Test
function. When you select
End Curr. Test
, any picker or magazine functions complete, and then the
diagnostic test stops.
To end a test
from the front panel:
1. While the diagnostic test you wish to stop is running, press
Escape
. The
Diagnostics
submenu displays.
2. On the submenu, scroll to
End Curr. Test
, and then press
Enter
.
User Abort
displays.