background image

 
 
 
 

Page 6 of 7 

Tel.: (+45) 9614 9614 

 Fax: (+45) 9614 9615 

 E-mail: [email protected] 

 
Temperature: -10…55°C 

(nominal) 

 -25…60°C 

(operating) 

 -25…65°C 

(storage) 

 

Temperature coefficient: Max. ±0.5% of full scale within -10…55°C 

 

according to IEC 51 and EN 60051 

 
Panel influence:  Linearity is not affected by the panel (thickness or material) 

according to IEC 51 and EN 60051 

 
Shock: 

18 x 50 g half sine (11mS) according to IEC 68-2-27. Test: Ea 

 
Vibration: 

3…13.2Hz: 2.0mm peak-peak (±1.0mm) according to GL + LR: 
Test 1 

 

13.2…100Hz: 0.7 g according to DNV: Class A 

 
Safety: 

300V – cat. III, pollution degree 2 according to EN 61010-1 

 
Galv. separation:  500V between all groups 
 
Supply voltage: 

Power supply:  24V DC -25/+30% (18…24…31.2V DC) 

 Illumination: 

12mA/24V 

DC 

 
Consumption: 

<3W (24V/120mA), excl. illumination 

 
EMC: 

CE marked for residential, commercial and light industry plus 
industrial environment according to EN 50081-1/2 and EN 50082-
1/2 

 
Class approval: 

Marine Equipment Directive 96/98/EC (MED) 

 
Connections: 

Separate screw terminals for instrument input, power supply and 
illumination  

 

Max. 2.5mm² multi-stranded or 4.0mm² single-stranded 

 
Materials: 

All outer materials are self-extinguishing according to UL94 (V0) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for DLQA96

Page 1: ...n with disc pointer Linearized to class 0 5 LED illumination of scale and disc 100 identical illumination of scale and disc Shock resistant up to 50 g Enclosure IP52 54 or IP66 only Q96 size Approved...

Page 2: ...6 0 69 0 68 3 19 19 19 90 x 90 136 x 136 90 x 90 103 150 103 12 12 12 92 x 92 0 8 137 x 137 1 0 92 x 92 0 8 0 230 0 385 0 250 The instrument is mounted by means of the 2 fixing elements For instrument...

Page 3: ...from ESD is needed When the instrument is mounted in the console switchboard the terminal on the rear side is connected to the cable The instrument is configured either for single input or for double...

Page 4: ...00mA 180 6 16 00mA 270 9 4 20mA Disc moves CW with posi tive input 20 00mA Not connected 360 12 0 00mA 0 12 0 25mA 90 3 0 50mA 180 6 0 75mA 270 9 0 1mA Disc moves CW with posi tive input 1 00mA Not co...

Page 5: ...gle May be mounted at any angle between 0 360 to horizontal without this affecting the linearity according to DIN 16257 Compass safety distance To be mounted at least 1m from the compass according to...

Page 6: ...3 2 100Hz 0 7 g according to DNV Class A Safety 300V cat III pollution degree 2 according to EN 61010 1 Galv separation 500V between all groups Supply voltage Power supply 24V DC 25 30 18 24 31 2V DC...

Page 7: ...t consump DLQA96 144 12mA 24V DC Galv separation 500V 50Hz 1 min between groups 3 groups If protection against voltage transients surge pulse for the auxiliary supply AUX 24V and input for ILLUM is re...

Reviews: