1. Description 

The illuminated X-coil instruments types DLQA96/144 are designed for marine 
applications. The instruments can be applied as rudder indicator, azimuth indicator, 
compass indicator or wind direction indicator where a reliable and accurate instrument 
is prescribed. 
 
The light intensity can be altered by means of a common dimmer for all instruments. 
Dimming of an instrument can be done by means of a 1k

 potentiometer. 

 

2. Mounting 

instructions 

DLQA96/144 is designed for installation in bridge consoles or switchboards. 
 

All dimensions in mm 
 
 
 
 
 
 
 
 
 
 
 
 
 

Type A 

(max.)

J Weight 

(kg) 

DLQA96 
DLQA144 
DLQAW96 

96 x 96 

144 x 144 
102 x 102 

4.5
4.5
5.3

5.5 
8.0 
4.2 

66.0
69.0
68.3

19 
19 
19 

90 x 90 

136 x 136 

90 x 90 

103
150
103

12 
12 
12 

    92 x 92 +0.8

137 x 137+1.0

    92 x 92 +0.8

0.230 
0.385 
0.250 

 
The instrument is mounted by means of the 2 fixing elements. For instruments with 
IP54 or IP66 protection, use all 4 fixing elements and the rubber gasket (included in 
the packing). 
 

3. Connection 

DLQA96/144 instruments differ from the other DLQ instruments, as the DLQA96/144 
instruments are based on an X-coil system and not on a moving-coil system like the 
other instruments in the product programme of DEIF A/S. Due to the X-coil technology 
it is possible to have an instrument with a scale curve of 360°, which is not possible in 
the conventional moving-coil systems. As the X-coil system requires a special 
controller integrated in the instrument, the DLQA96/144 instruments are to be 
connected to an auxiliary supply – unlike conventional instruments. The plugs marked 
PROG and COM are for factory use only.  
 

Summary of Contents for DLQA96

Page 1: ...n with disc pointer Linearized to class 0 5 LED illumination of scale and disc 100 identical illumination of scale and disc Shock resistant up to 50 g Enclosure IP52 54 or IP66 only Q96 size Approved...

Page 2: ...6 0 69 0 68 3 19 19 19 90 x 90 136 x 136 90 x 90 103 150 103 12 12 12 92 x 92 0 8 137 x 137 1 0 92 x 92 0 8 0 230 0 385 0 250 The instrument is mounted by means of the 2 fixing elements For instrument...

Page 3: ...from ESD is needed When the instrument is mounted in the console switchboard the terminal on the rear side is connected to the cable The instrument is configured either for single input or for double...

Page 4: ...00mA 180 6 16 00mA 270 9 4 20mA Disc moves CW with posi tive input 20 00mA Not connected 360 12 0 00mA 0 12 0 25mA 90 3 0 50mA 180 6 0 75mA 270 9 0 1mA Disc moves CW with posi tive input 1 00mA Not co...

Page 5: ...gle May be mounted at any angle between 0 360 to horizontal without this affecting the linearity according to DIN 16257 Compass safety distance To be mounted at least 1m from the compass according to...

Page 6: ...3 2 100Hz 0 7 g according to DNV Class A Safety 300V cat III pollution degree 2 according to EN 61010 1 Galv separation 500V between all groups Supply voltage Power supply 24V DC 25 30 18 24 31 2V DC...

Page 7: ...t consump DLQA96 144 12mA 24V DC Galv separation 500V 50Hz 1 min between groups 3 groups If protection against voltage transients surge pulse for the auxiliary supply AUX 24V and input for ILLUM is re...