18

 

 

 

 

 

Increase to maximum flame height takes place after double 
click of 

 button, what is confirmed with HI message. 

7.7.6.

 

TIMER 

Timer operates in Manual, Thermostatic and Eco(nomy) mode. 
Flame in the fireplace is damped after the set time has elapsed. 
Maximum  countdown  time  until  damping  is  9  hours  and  50 
minutes. 

 

Timer switch on 

 

Press and hold 

 the button until an icon   will appear on 

the screen, and the hour field of the counter start flashing. 

 

Use 

  buttons  to  set  hours  of  fireplace  operation. 

Confirm  the  setting  with 

  button.  Minute  field  will  start 

flashing. 

 

Set additional minutes using 

 

 buttons. Confirm with 

 button. 

Timer switch off 

 

Press 

 button, icon   and counter will disappear from the 

remote control screen and counting will be cancelled. 

7.7.7.

 

OPERATING MODES 

The heater may operate in one of three modes (buttons activating 

the given mode are red on the pictures): 

 

 

Thermostatic  mode  is  based  on  measurement  of  room 
temperature where the heater is located and control of flame 
height so as to maintain the temperature set in the controller. 

 

 

Programmed  mode  is  one  of  two  programs  set,  which 
specify  when  the  heater  should  operate  and  what 
temperature should be maintained. 

 

 

Eco mode controls the fireplace so as to maintain the set 
temperature, but in the more economical way. The controller 
forces maximum height of the flame if the temperature is too 
low. If the temperature is too high, then the minimum flame 
will be set. One cycle lasts approx. 20 minutes. 

7.7.8.

 

THERMOSTATIC MODE 

In  thermostatic  mode,  ambient  temperature  is  compared  with  a 

thermostat  temperature  and  the  fireplace  power  is  modulated 
correspondingly  to  the  difference  of  both  temperatures.  Ambient 
temperature is measured by a sensor installed in the remote control, 
therefore it should not be subjected to additional heat e.g. by exposing 
it to the direct sunlight. If the temperature of the remote control exceeds 
the ambient temperature, then measuring errors will cause cold spots 
in the room. 

Attention!!! 

Do  not  store  the  remote  control near  the  fireplace  or  in  a  place 
exposed to sunlight.  

 

 

Switch the mode on with 

 button. A thermometer icon will 

be displayed on the screen. Set temperature will be displayed 
next to this icon for a while and then room temperature will 
be shown. 

 

Press  and  hold  the  button  with  thermometer  until 
thermometer icon starts flashing. 

 

Set the temperature using 

 

 buttons.  

 

Confirm the temperature using button with thermometer. 

 

The mode is switched off after you: 

o

 

Press the 

 button. 

Summary of Contents for VITAL 37S

Page 1: ...erating manual gas fired convection room heater DEFRO HOME VITAL 37 S 51 S BP BL U C T gas type G2 350 G20 G27 G31 G30 translation of original operating manual edition 1 b May 2021 destination countri...

Page 2: ...deklaracja musi by przekazana wraz z urz dzeniem w przypadku odst pienia w asno ci innej osobie This Declaration of Conformity becomes invalid if any changes have been made to the device if its constr...

Page 3: ...illed copy of the Warranty Card to the following address DEFRO Sp z o o Sp k Centrum Serwisowe Ruda Strawczy ska 103a 26 067 Strawczyn serwis defro pl By sending back your Warranty Card you will be re...

Page 4: ...2 Preparation 16 7 3 Information 16 7 4 Deactivation of remote control function 16 7 5 Activation of remote control function 16 7 6 Control of FIREPLACE with a remote control 16 7 6 1 Setting temperat...

Page 5: ...34 13 PRODUCT WARRANTY TERMS AND CONDITIONS 35 13 1 Warranty conditions 48h Service 36 14 WARRANTY CARD 37 15 CARRIED OUT WARRANTY REPAIRS AND MAINTENANCE 38 16 WARRANTY CARD copy to send back 39 17...

Page 6: ...m the action of high temperature Non compliance with the recommendations distinguished in this way may cause a fire or burns Hint Informative symbol Useful information and hints are marked in this way...

Page 7: ...The body of the heater is made of steel sheet with combustion chamber located inside and lined with additional panels made of sheet rear and sides Picture 1 Design of DEFRO HOME VITAL heater 1 explos...

Page 8: ...pply V DC 6 Weight1 kg 90 90 90 90 90 1 Device weight depends on selected design version and its equipment 2 Level for C11 equipment acc to PN EN 613 2002 A1 2004 Table 2 Technical data of GV60 regula...

Page 9: ...O HOME VITAL 51 S U Picture 8 Dimensions of DEFRO HOME VITAL 51 S T Picture 9 Dimensions of DEFRO HOME VITAL 51 S 983 47 808 330 297 150 883 370 115 98 111 783 188 350 828 309 781 370 107 98 154 720 4...

Page 10: ...ts pressure and whether the current settings of a heater are correct VITAL heater should be supplied with the same type of gas as the other gas fired equipment if any in the home of their installation...

Page 11: ...reduction of total allowable length of the pipe by 1 meter First elbow connected to the equipment is not taken into consideration Vertically lead pipes should be fixed to the wall using brackets arra...

Page 12: ...f the existing chimney in connection with a terminal should be protected against flooding or clogging and the terminal should be installed in a way ensuring its correct operation Penetration of concen...

Page 13: ...y burner by turning the screw clockwise rotation increases the pressure When the adjustment has beencompletedyoushouldprotect the following fixtures with blanking plugs pressure control screw and afte...

Page 14: ...tion of concentric coaxial system acc to allowed configuration for ducts leading set the flue gas flow damper in half of opening position Close the window panel and set maximum load of the heater Meas...

Page 15: ...of contact with wooden wall or wall made of other inflammable material it is appropriate to insulate flue gas discharge pipe In case of floor made of inflammable materials it is appropriate to prepar...

Page 16: ...control knob to ON Make sure that four 4 AA batteries have been correctly installed in the receiver Remote control operating at the 868 MHz band also requires preparation You should enter the transmi...

Page 17: ...tton firing with one button on remote control or two button and at the same time firingup with two buttons until twoshort audible signals will be heard and an icon confirming the ignition will be flas...

Page 18: ...what temperature should be maintained Eco mode controls the fireplace so as to maintain the set temperature but inthemore economical way Thecontroller forces maximum height of the flame if thetempera...

Page 19: ...ed once again for a while and minutes field will be flashing Select minutes using buttons Confirm the setting once again with the button The system will go to configuration of switch off time Switch o...

Page 20: ...in manual control mode All operations are then performed directly from the GV60 valve level located inside the cabinet Control components used during manual control are presented on the picture 24 To...

Page 21: ...ion locked for two minutes Second thermocouple in incorrect position Incorrect connection of cables of the second thermocouple Decorative items installed incorrectly Clogged openings of the primary bu...

Page 22: ...ange of settings No flame control from controller level No WiFi connection with WiFi module of the controller Switched off WiFi connection on the control device F42 Check WiFi Flame does not respond t...

Page 23: ...omponents should not touch the window panel Components should not cover the flame of the control burner It is forbidden to cover outlet holes of the primary burner and gaps in the floor of the combust...

Page 24: ...installation of chunks 2 Lay item no 1 as presented on both photos The component should remain stable at the centre of the ignition burner and parallel to the rear wall The wider end of thechunk shoul...

Page 25: ...th photos Chunk should be stable due to incisions adapted to the burner The distance between the holes in the burner and the edge of the chunk should be approx 5 mm right corner of the burner the edge...

Page 26: ...c to the incision and photos Similarly as for chunk no 2 the distance between the holes in the burner and the edge of the chunk should be approx 5 mm left corner of the burner the edge of the ceramic...

Page 27: ...27 5 Lay chunk no 4 as presented on the photos The chunk should not cover burner openings and should be supported in half way on chunk no 1 gas holes...

Page 28: ...28 gas holes left corner of the burner...

Page 29: ...29 6 Lay item no 5 as presented on photos The chunk should be stable and should not cover gas openings in the floor right corner of the burner gas gaps...

Page 30: ...30 7 Set the chunk no 6 as the last one it should be laid on chunk no 5 and be supported on chunk no 4 and right corner of the burner...

Page 31: ...31 right corner of the burner...

Page 32: ...32 8 3 LAYING OF DECORATION IMITATING THE STONES Items made of stone should be laid on the floor of the combustion chamber so as to avoid covering of gas openings...

Page 33: ...or this purpose they should not be used on other surfaces or components e g painted because they may damage them 9 2 WINDOW PANEL DISMANTLING To clean the window panel combustion chamber or install de...

Page 34: ...arbon monoxide is a result of defect or leaks in the system Given the impossibility to detect presence of this hazardous gas you should Perform inspections of the system and its maintenance by authori...

Page 35: ...pr assembly of window panels iv decorative items supplied with the equipment or purchased by the customer v all damages resulting from incorrect transport from distributor to the customer incorrect i...

Page 36: ...accept the claim and to charge its costs to buyer 25 Provisions of this document shall not limit in any way the rights resulting from the claim filed based on the statutory guarantee The warranty doe...

Page 37: ...s been delivered as complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation manual with this War...

Page 38: ...38 15 CARRIED OUT WARRANTY REPAIRS AND MAINTENANCE No date fault description repaired element description of repairs comments Stamp and signature of Service 1 2 3 4 5 6 7 8 9 10...

Page 39: ...s been delivered as complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation manual with this War...

Page 40: ...40...

Page 41: ...technician Way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date Justness of complaint Duration of repair Fault defect has been removed th...

Page 42: ......

Page 43: ...hnician Way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date Justness of complaint Duration of repair Fault defect has been removed the eq...

Page 44: ......

Page 45: ...technician Way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date Justness of complaint Duration of repair Fault defect has been removed th...

Page 46: ......

Page 47: ...47 20 REGISTER OF INSPECTIONS OF SMOKE DUCTS date stamp and signature of chimneysweep date stamp and signature of chimneysweep...

Page 48: ...mbol Unit value Heat output Rated heat output Pnom kW 6 0 Minimum heat output Pmin kW 3 6 Performance Performance at rated thermal power th nom Performance at minimal thermal power indicative th min A...

Page 49: ...ol Unit Value Heat output Rated heat output Pnom kW 5 5 Minimum heat output Pmin kW 3 3 Performance Performance at rated thermal power th nom Performance at minimal thermal power indicative th min Aux...

Page 50: ......

Page 51: ...51...

Page 52: ...509 702 720 509 577 900 DEFRO Sp ka z ograniczon odpowiedzialno ci Sp ka komandytowa 00 403 Warszawa ul Solec 24 253 Production plant Ruda Strawczy ska 103 A 26 067 Strawczyn tel 41 303 80 85 biuro d...

Reviews: