5
SAFETY
•
Do not do incorrect connections even though the charge output is protected against short circuiting and wrong connections.
•
The charger does not draw current from the battery when the main power is not connected.
•
Do not install the charger in a highly flammable environment.
•
Do not charge a damaged battery.
•
During charging, battery gas which is very explosive can be developed. Take care not to have sparks, open flames,
cigarettes or similar in the vicinity of the battery and make sure there are sufficient ventilation.
•
The acid in the battery is corrosive and harmful. It damages clothes, metal and varnish. In case of spillage and contact with skin,
wash and rinse thoroughly with water and consult a doctor.
•
Lead and other chemicals that are used in batteries are toxic. Wash skin and hands thoroughly after working with batteries.
•
Always read battery instructions.
WARRANTY
The guarantee applies to faults in production and materials for 2 years from date of purchase. The customer must deliver the product back to the place
of purchase together with the receipt. The guarantee shall cease to apply if the charger is handled negligently, opened or repaired by someone other than
DEFA or an authorized representative of DEFA. DEFA has no other guarantee than this and will not be responsible for other costs than those referred to, i.e.
no possible additional costs. Neither is DEFA bound by any other guarantee.
TECHNICAL INFORMATION
Electrical data input
Mains voltage
~ 230 V AC
Mains frequency
50/60 Hz
Mains current
max. 2.9 A eff.
Efficiency
max. 95 %
Effective power
max. 560 W
Power consumption (standby)
max. 1.7 W
Protection class
I
EMC emission
Class A
Electrical data output
Nominal output voltage
12 V DC / 6 cells
Output voltage range
2 V – 15.3 V DC
Output current
32 A at 14,4 V DC
Battery return current
< 1 mA
Mechanical data
Cooling
Convection
Dimensions (l x w x h)
227 x 125 x 62 mm
Weight (without cable)
1.7 kg
AC Power cable length
5 m
DC charging cable length
2,5 m
Environmental conditions
Operating temperature
-20°C - +40°C
Storage temperature
-40°C - +85°C
Climate class
B
Degree of protection
Horizontal position IP40
Vertical position IP44
Standards
EN 60335-1, EN 60335-2-29, EN 61000-6-2 (EN 61000-4-2,
EN 61000-4-3, EN 61000-4-4) (EN 61000-4-5, EN 61000-4-6,
EN 61000-4-11), EN 61000-6-4 (Class A)
DEFA confirms that these chargers satisfy relevant safety requirements according to prevailing regulations and standards.