1 0
| O A S I S P O L Y C A R B O N A T E V E R A N D A I N S T A L L A T I O N G U I D E
1 1
5.4 JOINING PATIO ROOFS
There is no limit to the width in which the Deeplas patio roofs can be delivered. This is because the patio roofs can be joined end to
end. In this case the gutter profile, wall profile and decorative profile are supplied in multiple lengths of 4060, 5060 or 6060mm.
The centre-to-centre distance between the rafters of a Deeplas patio roof is 1000mm (1 metre). A roof with five one-metre sections
has a total width of 5060mm. The extra 60mm is the distance from the centre of the rafter to the outside of the rafter, which is
30mm; this extra width is at both ends, for a total of 60mm.
When standard size sheets are used, the total width of joined roofs must therefore also end with 60mm, e.g. 8060, 9060, 10060, etc.
So if you have ordered a roof with a width of 9060mm, the delivery will consist of one 5060mm gutter section and one 4060mm
gutter section. Together this is 9120mm. You must ensure that the width ends with xx60, so these profiles must be shorted by a total
of 60mm before installation. This can be done by removing 30mm from both sections: 4030mm = 9060mm. You can also
choose to shorten one profile by 60mm. 4000mm = 9060mm. This shortening applies to the wall profile, gutter profile
and decorative profile. After this shortening the further assembly is identical to that for a normal roof.
www.deponti.com
Patio Roof Manual – Type Bosco
14
1000mm
30mm
30mm
5000mm
5060mm
1000mm
1000mm
1000mm
1000mm
5.4 Joining patio roofs
There is no limit to the width in which the Deponti patio roofs can be delivered. This is because the
patio roofs can be joined end to end.
In this case the gutter profile, wall profile and decorative profile are supplied in multiple lengths of
4060, 5060 or 6060 mm.
The centre-to-centre distance between the rafters of a Deponti patio roof is 1000 mm (1 metre).
A roof with five one-metre sections has a total width of 5060 mm. The extra 60 mm is the distance
from the centre of the rafter to the outside of the rafter, which is 30 mm; this extra width is at both
ends, for a total of 60 mm.
When standard size sheets are used, the total width of joined roofs must therefore also end with 60
mm, e.g. 8060, 9060, 10060, etc.
So if you have ordered a roof with a width of 9060 mm, the delivery will consist of one 5060 mm
gutter section and one 4060 mm gutter section. Together this is 9120 mm. You must ensure that the
width ends with xx60, so these profiles must be shorted by a total of 60 mm before installation. This
can be done by removing 30 mm from both sections: 5030 mm + 4030 mm = 9060 mm. You can also
choose to shorten one profile by 60 mm. 5060 mm + 4000 mm = 9060 mm.
This shortening applies to the wall profile, gutter profile and decorative profile.
After this shortening the further assembly is identical to that for a normal roof.
Summary of Contents for OASIS POLYCARBONATE VERANDA
Page 35: ...3 5 DESIGN GRID ...