Draft
Nuisance
This is a repetitive detector value. When an alarm is received on
the unit, it will store the alarm time and monitor the number of times
the same detector is triggered within an hour period. If the detector
is triggered the number of times entered here, the unit will de-
activate this detector from triggering an alarm for an hour. The unit
will continue to monitor the detector and check how many times it
is triggered during this period. If it is again triggered more than the
amount set in the nuisance counter, it will remain de-activated for
another hour. This will continue until the trigger value falls below the
nuisance count setting. To disable this feature, leave the setting as ‘0’.
Stuck Time (min)
If any of the alarms/detectors are active for a period longer than
specified here, they will automatically be omitted. This time period is
set in minutes.
Reset (Red)
This button will restart the unit.
Relays (Green)
Opens the Alarm Settings -> Global Actions page
Status (Yellow)
Opens the System Settings -> Status -> Alarm Status Page
Zone In (Blue)
Opens the Zone Inputs page (below).
Refresh (Purple)
Refreshes the current page.