Open
stopcock
Move slide control / Ignition button at the gas fired boiler onto ignition symbol
Press ignition button and keep it down
Check at inspection window, if ignition flame is burning
In case of burning of the ignition flame keep on pressing the button for another 10
seconds.
Please note:
Firmly secure the gas bottles – gas bottles may not be connectiong during a
journey – close gas bottle during the journey
3.4.5 Negative pressure plant (optional equipment)
To avoid the danger of the spreading of dust out of the dirty area to the clean area, all
rooms are ventilated. In the dirty area, the air is sucked in and blown out through P3
filters.
Negativ pressure plant
Negative pressure plant
Inspection window
Stopcock
Slide control / Ignition
button