3.4.8 Filter change
filter change only when device is deactivated
dismount the dirty filters in a wet state in order to avoid the release of filter dust
only use authorized filters
damaged filter candle may not be used
The sewage water filters have to be changed if the power of the sewage water
pump decreases. We recommend by normal consumption of dirty water a weekly
change, by stronger strain a daily change.
Slacken cap nut
Take out the filter and dispose of it
Keep filter glas and sealing face clean
Insert new filter candles
Screw on cap nut with key carefully
Suction hoses, pumps, filter housings and filter are already contaminated by the
first use. Repairs and maintenance works are only allowed to be undertaken in
observing the security measures.
All mentioned filters must be disposed of according to the regulations required by
law.
3.4.9 Light
Through the activation of the switch light, the LED-lighting in the vehicle is switched on.
Light
Key
Summary of Contents for decontamination mobile D 3000
Page 39: ...Guide book D 3000 4000 5000 Seite 39 6 2 Circuit vehicle lighting for all versions identical...
Page 41: ...Guide book D 3000 4000 5000 Seite 41 6 4 Circuits vehicle technology Electric Version...
Page 42: ...Guide book D 3000 4000 5000 Seite 42...
Page 44: ...Guide book D 3000 4000 5000 Seite 44...
Page 45: ...Guide book D 3000 4000 5000 Seite 45...
Page 46: ...Guide book D 3000 4000 5000 Seite 46 6 6 Circuits vehicle technology Diesel Version...
Page 47: ...Guide book D 3000 4000 5000 Seite 47...
Page 48: ...Guide book D 3000 4000 5000 Seite 48 6 7 Circuits vehicle technology Gas Version...