Through the fresh air openings, the shower and the clean area are also ventilated. The
fresh air openings have been scaled in such a way that a pressure drop prevails going
from the dirty area to the clean area.
3.4.6 Shower
The showering procedure can be started and stopped by the mixer tap.
3.4.7 Sewage water filtering plant (optional equipment)
If the switch „Sewage water filtering plant“ is switched on in the technical room, the
sewage pump starts automatically if you switch the switch „shower water start“ and
pumps the dirty shower water via 2 steps filtering plant. The filtered sewage water comes
out at the connection „filtered sewage water“.