background image

 

 

Instruction manual

 

 

Water treatment boiler system D 110 L 

 

 

 

 

 

 

Seite 3 

 

1 Basic safety advice 

 

The handling of the appliance technology is only allowed for instructed staff

The exact 

knowledge of the guide book is an important condition for the staff before handling the 
machine. 
 
Please keep the instruction manual close to hand and available for everybody. 

deconta

 has to engage you as the user to follow the guide book and to employ this 

engineered technology only in accordance with the regulations and not in a inappropriate 
way! In the event of non-observance, 

deconta

 assumes no liability. 

 
To ensure safety during operation of the unit, the following must be strictly observed: 
 

  Do not use in potentially explosive areas. 

  Necessary repairs and maintenance may only be performed by authorized staff. 

 

For all repair and maintenance work, the device is to be completely disconnected 
from power supply 

 

 

The safety and protective equipment is to be kept in perfect function.

 

 

Attached safety guidelines are to be kept in a readable state and are to be 
followed.

 

  Generally applicable legal and other binding regulations for accident prevention 

and handling of hazardous substances must be observed.  

 
In order not to restrict safety, any changes on the machine are prohibited. 

 

Summary of Contents for D 110L

Page 1: ...Instruction manual Water treatment boiler system D 110 L Manufacturer deconta GmbH Im Geer 20 D 46419 Isselburg Description Water management D 110 L Type No 503 Serial No...

Page 2: ...L Seite 2 Table of contents on page 1 Basic safety advice 3 2 Transport und storage 4 3 Volume of delivery 5 4 Technical description 5 5 Technical data 7 6 Initial operation 8 7 Maintenance and care...

Page 3: ...n the event of non observance deconta assumes no liability To ensure safety during operation of the unit the following must be strictly observed Do not use in potentially explosive areas Necessary rep...

Page 4: ...to avoid damages due to faulty handling or imprudence In winter and at risk of frost you have to empty the whole device pumps filter housings tank preliminary to the transport Attention Transport of...

Page 5: ...o regulations During asbestos sanitation works within closed rooms you have to exclude that the asbestos fibres leave the sanitation area uncontrolled and endanger the human health and the environment...

Page 6: ...9 10 11 12 13 14 15 16 17 0 10 20 30 40 50 60 70 80 90 100 0 77 0 97 1 22 1 54 1 93 2 44 3 07 3 87 4 87 6 14 7 74 9 75 12 3 15 5 19 5 24 6 30 9 Meas Point Diameter Effectiveness 1 0 77 84 3 2 0 97 90...

Page 7: ...2000Watt Heatup phase 37 C with full tank approx 2 h Pumps 12 V 6 5 A Self priming and dry run safe Flow rate max 10 6 l min Fresh water supply automatic via fresh water connection or manually via fi...

Page 8: ...ect to power supply Adjust temperature at heating rod the heating rod works at all switch settings of the function switch but not before a sensor controlled minimum fill level is reached At use of the...

Page 9: ...hower water pump sewage pump and heating rod operative Safety advice During works on the device always disconnect the plug Operate the device only with mains which are secured with fault current prote...

Page 10: ...ter change only if the device is switched off Demount dirty filters only in wet shape to avoid contamination Use only approved filters It is prohibited to use damaged filter candles Filter change Loos...

Page 11: ...1 7 4 Cleaning sewage pump Remove cover plate Remove hoses Remvoe fastening screws of pressure switch ATTENTION Do not alter the middle adjusting screw Remove fastening screws of pump head and take of...

Page 12: ...Instruction manual Water treatment boiler system D 110 L Seite 12 Take out valve plate and clean front and back Valve plate...

Page 13: ...Instruction manual Water treatment boiler system D 110 L Seite 13 8 Circuit diagram...

Page 14: ...ied harmonised standards EN 292 EN 60335 1 Applied national standards DIN VDE 0701 DIN VDE 0702 A Evers Leitung Entwicklung Isselburg 23 02 2011 The copyright of this instruction manual remains the pr...

Reviews: