7 Maintenance and care 

7.1 Maintenance 

 

Only undertake the maintenance works under the observance of all relevant safety 
precautions, the filter is contaminated! 

 

7.2 Daily maintenance 

  Check hoses on tightness and continuous flow 

  Visual check if pre filters are dirty 

 

7.3 Filter change 

 

Attention: 

 Filter change only if the device is switched off 

 

 

 

 Demount dirty filters only in wet shape to avoid contamination 

 

 

 

 Use only approved filters 

 

 

 

 It is prohibited to use damaged filter candles  

 
 

Filter change: 

 Loose the nut 

 

 

 

 Take out the filter and dispose of it 

 

 

 

 Insert the new filter candles 

 

 

 

 

Tighten

 the nut 

 
 

The suction hoses, pumps, filter housings and filter are contaminated after the first 
use. Repairs and maintenance have to be executed only under the observance of 
all relevant safety measures. All the filters mentioned have to be disposed of 
according to the legal terms. 

Summary of Contents for D 110L

Page 1: ...Instruction manual Water treatment boiler system D 110 L Manufacturer deconta GmbH Im Geer 20 D 46419 Isselburg Description Water management D 110 L Type No 503 Serial No...

Page 2: ...L Seite 2 Table of contents on page 1 Basic safety advice 3 2 Transport und storage 4 3 Volume of delivery 5 4 Technical description 5 5 Technical data 7 6 Initial operation 8 7 Maintenance and care...

Page 3: ...n the event of non observance deconta assumes no liability To ensure safety during operation of the unit the following must be strictly observed Do not use in potentially explosive areas Necessary rep...

Page 4: ...to avoid damages due to faulty handling or imprudence In winter and at risk of frost you have to empty the whole device pumps filter housings tank preliminary to the transport Attention Transport of...

Page 5: ...o regulations During asbestos sanitation works within closed rooms you have to exclude that the asbestos fibres leave the sanitation area uncontrolled and endanger the human health and the environment...

Page 6: ...9 10 11 12 13 14 15 16 17 0 10 20 30 40 50 60 70 80 90 100 0 77 0 97 1 22 1 54 1 93 2 44 3 07 3 87 4 87 6 14 7 74 9 75 12 3 15 5 19 5 24 6 30 9 Meas Point Diameter Effectiveness 1 0 77 84 3 2 0 97 90...

Page 7: ...2000Watt Heatup phase 37 C with full tank approx 2 h Pumps 12 V 6 5 A Self priming and dry run safe Flow rate max 10 6 l min Fresh water supply automatic via fresh water connection or manually via fi...

Page 8: ...ect to power supply Adjust temperature at heating rod the heating rod works at all switch settings of the function switch but not before a sensor controlled minimum fill level is reached At use of the...

Page 9: ...hower water pump sewage pump and heating rod operative Safety advice During works on the device always disconnect the plug Operate the device only with mains which are secured with fault current prote...

Page 10: ...ter change only if the device is switched off Demount dirty filters only in wet shape to avoid contamination Use only approved filters It is prohibited to use damaged filter candles Filter change Loos...

Page 11: ...1 7 4 Cleaning sewage pump Remove cover plate Remove hoses Remvoe fastening screws of pressure switch ATTENTION Do not alter the middle adjusting screw Remove fastening screws of pump head and take of...

Page 12: ...Instruction manual Water treatment boiler system D 110 L Seite 12 Take out valve plate and clean front and back Valve plate...

Page 13: ...Instruction manual Water treatment boiler system D 110 L Seite 13 8 Circuit diagram...

Page 14: ...ied harmonised standards EN 292 EN 60335 1 Applied national standards DIN VDE 0701 DIN VDE 0702 A Evers Leitung Entwicklung Isselburg 23 02 2011 The copyright of this instruction manual remains the pr...

Reviews: