G
3
™
U
se
r’s
&
In
sta
lla
tio
n M
an
ua
l
7/October/2020
72
Appendix B: Communications Port - serial protocols.
G3™ COM X serial outputs selections:
COMX setting Output
0 No output
1 Diagnostic output
2 Linear spectrum output
3 Future expansion
4 Future expansion
5 Future expansion
6 Future expansion
7 G3™ standard output
8 COPS (Common Output Protocol) Please contact
your local sales or service agent for protocol
description .
9 Power dB spectrum output
G3™ Standard Output:
The standard serial communication has the following characteristics
(8N1) and is transmit only:
• One (1) start bit
• Eight (8) data bits
• No parity
• One (1) stop bit
• Transmission at 1200 baud
The G3™ transmits data as ASCII symbols in the following digit
sequence:
Target
Patrol
[hundreds][tens][ones]
[hundreds][tens][ones]<CR>
(<CR> = ASCII decimal value 13)
The G3™ sends the data in this sequence when the TARGET or PATROL
speed display changes, or when the MODE or antenna selection
changes . During the test sequence the target and patrol speeds
transmit, but the display segment check data do not .
When you press the LOCK button, the G3™ transmits the following
digital sequence:
[hundreds][tens][ones]<CR>
(<CR> = ASCII
decimal value 13)
Summary of Contents for G3
Page 2: ......
Page 3: ...G3 User s Manual Installation Guide CanadaVariant Revision 7 October 2020 ...
Page 66: ...G3 User s Installation Manual 7 October 2020 66 ...
Page 74: ...G3 User s Installation Manual 7 October 2020 74 USER NOTES ...
Page 75: ......
Page 76: ...www DecaturElectronics com 16990 Goldentop Road San Diego CA 92127 USA 800 428 4315 ...