6. Installing the Probes
20
Figure 2: 5TE installed correctly
The probes may be difficult to insert into extremely compact
or dry soil. If you have difficulty inserting the probe, try loos-
ening the soil somewhat or wetting the soil. Never pound the
probe in.
Method 1. : Horizontal Installation
Excavate a hole or trench a few centimeters deeper than the
depth at which the sensor is to be installed. At the installation
depth, shave off some soil from the vertical soil face exposing
undisturbed soil. Insert the sensor into the undisturbed soil
face until the entire sensing portion of the 5TE is inserted.
The tip of each prong has been sharpened to make it easier to