24G SERIES FLATBOTTOM GAS FRYERS
CHAPTER 5: CONTROLLER OPERATION
5-2
5.1 Operating Fryers with Thermatron Controllers (cont.)
MANUAL FILTER POWER SWITCH
(
older systems with built-in filtration
)
– Controls power to
the filter pump in the event the primary system fails.
Fryer Power Switch should be in
"
OFF
"
position when in use.
HIGH-LIMIT RESET
– Located under control panel. Must be manually reset if the fryer exceeds
high-limit setpoint.
FILTER RESET BREAKER
(7 Amp Circuit Breaker- 120VAC or 5 Amp Circuit Breaker-
230VAC) – the breaker is inline between the filter switch and the pump. Ensure filter power is off
prior to resetting or replacing.
5 AMP (115VAC) or 2 AMP (230VAC) FUSE
– each fryer circuit is protected by a 5-amp
(115VAC) or 2-amp (230VAC) fuse located under the control panel or inside the cabinet.