Force adjustment
5.1
Force adjustment while closing
1. Press and hold the
key until the display shows P1;
2. Scroll down the parameters with
/
keys until the di-
splay shows P2;
3. Confirm by pressing the
key;
4. Pressing the
/
keys, set the desired value;
5. Confirm by pressing the
key;
6. After completing this operation the display shows “- -“.
Warning:
After adjustments, check the force set on the door to
secure the installation.
5.2
Force adjustment while opening
1. Press and hold the
key until the display shows P1;
2. Scroll down the parameters with
/
keys until the di-
splay shows P5;
3. Confirm by pressing the
key;
4. Pressing the
/
keys, set the desired value;
5. Confirm by pressing the
key;
6. After completing this operation the display shows “- -“.
Warning:
After adjustments, check the force set on the door to
secure the installation.
6
Photocells
1. Press and hold the
key until the display shows P1;
2. Scroll down the parameters with
/
keys until the di-
splay shows P3;
3. Confirm by pressing the
key;
4. Pressing the
/
keys, set:
- H0=photocells deactivated;
- H1=photocells activated;
5. Confirm by pressing the
key;
6. After completing this operation the display shows “- -“.
Warning:
If photocells are not used, set P3=H0.
7
Automatic closing
1. Press and hold the
key until the display shows P1;
2. Scroll down the parameters with
/
keys until the di-
splay shows P4;
3. Confirm by pressing the
key;
4. Pressing the
/
keys, set the desired value;
Each increment of the parameter value, increases of 1 minute
the delay in closing up to a maximum of 9 minutes.
5. Confirm by pressing the
key;
6. After completing this operation the display shows “- -“.
Warning:
The default value is P4=b0 (deactivated). If this function is
active, it starts once the door opening position is reached.