4.23. UNIT’S TAIP REFERENCE
4.23.9
(GT) Time Window
Qualifiers
:
Q
,
S
,
R
This message is used to configure the
Time Windows
that can be used
to trigger events. The signal associated with a
Time Window
becomes
active when the actual date and time is between the values set by the
TMin
and
TMax
parameters. Note: The minimum time between TMin
and TMax is 2 minutes. The message has the following format:
AAB[CCCCCCDDDDDDEEEEEEFFFFFF]
Chars
Item
Format
Value
Meaning
2
Time
win-
dow ID
AA
00-09
Identification code assigned to
time window.
1
Active flag
B
flag
1: Time window is active.
U: Delete Time window.
6
TMin[Day]
CC/CC/CC
yy/mm/dd
Date at beginning of time win-
dow.
6
TMin[Time]
DD:DD:DD
hh:mm:ss
Time at beginning of time win-
dow.
6
TMax[Day]
EE/EE/EE
yy/mm/dd
Date at end of time window.
6
TMax[Time]
FF:FF:FF
hh:mm:ss
Time at end of time window.
If a day is not specified (TMin[Day] and TMax[Day] are both 000000),
TMin[Time] and TMax[Time] specify a periodic window.