4.23. UNIT’S TAIP REFERENCE
4.23.58
(XAZZ) Buzzer alerts
Qualifiers
:
S
,
R
,
Q
Using this command, different audible alerts can be generated.
A
Chars
Item
Format
Value
Meaning
1
type
A
0-2
Audible alert
0
Stop an audible alert.
1
A beep is continuously gener-
ated every second.
2
A three-seconds long beep is
generated once.
197