3.11 OXYGEN SYSTEM
Description
The oxygen system includes a liquid oxygen tank with a capacity of 5 litres and an emergency
gaseous oxygen cylinder with a capacity of 0.4 litres at 180 bar. This provides an oxygen tank
duration that varies from 4 to 11 hours 30 minutes, depending on the pilot, type of flight,
altitude and operation mode of the regulator. The emergency cylinder has a duration of 7
minutes in case of ejection.
Operation with oxygen tank:
Normal
o
Selector set to N: Letter N shown in the magnetic indicator. A mixture of oxygen
and air, which varies with altitude, is supplied on demand, and pure oxygen
above 33,000 ft.
o
Selector set to 100%: White square shown in the magnetic indicator. Pure
oxygen is supplied on demand at any altitude.
Emergency
o
Selector set to EMG (S): Red square shown in the magnetic indicator. A mixture
of air and oxygen, which varies with altitude, is supplied on continuous flow
Controls and indicators
Figure 3-73 Pilot’s Personal Equipment Connector
1 N-100%-EMG MODE SELECTOR SWITCH
2 OXYGEN OVERPRESSURE BUTTON
3 ANTI-G CONNECTION COVER
1
2
3
Summary of Contents for AERGES MIRAGE F1
Page 1: ...DCS Mirage F1 Flight Manual Version 1 0 1 MIRAGE F1 for DCS World Flight Manual ...
Page 6: ...DCS Mirage F1 Flight Manual Version 1 0 6 ...
Page 9: ...DCS Mirage F1 Flight Manual Version 1 0 9 ...
Page 12: ...DCS Mirage F1 Flight Manual Version 1 0 12 ...
Page 100: ...DCS Mirage F1 Flight Manual Version 1 0 100 ...
Page 110: ...DCS Mirage F1 Flight Manual Version 1 0 110 Figure 4 4 GCA or ILS Pattern ...
Page 114: ...DCS Mirage F1 Flight Manual Version 1 0 114 ...
Page 118: ...DCS Mirage F1 Flight Manual Version 1 0 118 ...
Page 122: ...DCS Mirage F1 Flight Manual Version 1 0 122 ...
Page 129: ...DCS Mirage F1 Flight Manual Version 1 0 129 ...
Page 131: ...DCS Mirage F1 Flight Manual Version 1 0 131 ...