Time Operated Purge Valve
To Replace the Time Operated Purge Valve
1. Remove the Philips head screw that holds the electrical connector in place, and pull the electrical connector off of the timer assembly.
2. Turn “OFF” the strainer / shutoff valve in Fig. N.
3. Remove the valve and replace with DCI Part Number 2011 for 230 volt machines OR DCI Part Number 2848 for 115 volt models.
4. Return the strainer / shutoff valve to the On position.
NOTE: Make sure the coil voltage matches that of the machine data tag.