25
temperature risen high, The heating element will stop working
remaining the motor fan.You should take out the power cord until the
temperature is down to normal, then you could connect the power
code to turn on it, the Heating element will recover a normal work.
*Non-self-resetting thermal cut-out protection function:
This
product equip with Non-self-resetting thermal cut-out device. Once
appearing accident, like short circuit, the function will permanently
cut off the power, preventing from the occurrence of trouble.
*Regulating the thermostat for fan heater:
You could regulate the
room temperature by the thermostat.The thermostat is designed to
control the room temperature rougly from 0-32 degree.
*Anti-dumping function for fan heater:
When the heater fall down
during the fan heater working,the anti-tilt switch will be activated to
turn off the heating element.
3. Used in Cold breeze or Hot Breeze two function
The breeze machine of this product can choose to blow cold breeze