to hold the control knob down for 10-15 seconds more. Release

the button i

the pilot fame goes out repeat the above operation

HEAT SETTINGS

To change from minimum to maximum gently press control button
and turn it position 3.
To change from maximum to medium gently press control button
and turn it position 2.

Turn off heater at cylinder or turn the switch on the regulator to the
“OFF” position. If the heater is not be used for a period of time
disconnect the regulator from the cylinder and replace any value
protection plug or cover

Attention!

Please do not forcefully turn the control knob, the button should be
pushed down before changing the heat control settings. The control
button will not turn without pushing downwards. Ensure the button
is locked into the heat setting /position required.

2.HEATING FAN OPERATION:

Importan:The fan heater could start to work after the thermostat turn
on.

1) Control knob of thermostat
To use the fan heater,you should regulate the temperature by the

thermostat

rst.Turn the thermostat knob clockwise,once you hear

a “Click”,that means the thermostat start to work.You could set up
the temperature from 0-32 degree roughly,then to turn on the fan
heater.To turn off the fan heater,you could turn the thermostat knob
anti-clocksise until you hear a “Click” or by the button of the fan
heater.

Summary of Contents for GH05

Page 1: ......

Page 2: ...INJURY OR LOSS OF LIFEWARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE TECHNICAL CHARACTERISTICS...

Page 3: ...H Weight kg 9 5 kg Weight kg 9 5 kg SAFETY PRECAUTIONS 1 Always use Heater in accordance with instructions supplied with each heater Keep instructions in a safe place 3 DO NOT position heater close fu...

Page 4: ...uld be positioned on a level surface at all times 6 If a leak is suspected DO NOT disconnect the regulator Turn off the gas supply at the gas bottle or gas regulator Take the appliance outdoors in a f...

Page 5: ...n use For this reason adequate ventilation should be provided in rooms in which the heater is used This ensures the removal of products of combustion and allows the entry of replacement air Adequate v...

Page 6: ...the last use light the heater outside and burn outdoors for 15 minutes 10 Do not use your heater while sleeping 11 Do not use your heater in high rise fats 12 Do not use your heater in basements bathr...

Page 7: ...the standard of EN1763 1 Class 3 The hose used must conform to the relevant standard for the country of use The length of the hose must be 0 5m maximum Worn or damaged hose must be replaced Ensure tha...

Page 8: ...pilot fame b Ensure good connection between thermocouple and valve c Check thermocouple d Check electromagnetic valve 4 After changing to maximum position with all three plaques alight one or more pla...

Page 9: ...bing and the valve 3 Turn the cylinder and the regulator on 4 Where the regulator is not supplied or is missing please contact your gas dealer to advise of the correct type for the gas cylinder being...

Page 10: ...ving and replacing the cylinder Do not attempt to replace the cylinder whilst the heater is still in use 2 Cylinders must be replaced in a fame ree environment 3 Do not smoke while changing the cylind...

Page 11: ...t out device Once appearing accident like short circuit the function will permanently cut off the power preventing from the occurrence of trouble Regulating the thermostat for fan heater You could reg...

Page 12: ...3 b The electric heater has two function cold breeze and heating element 1 GAS KNOB CONTROL LIGHTING Turn on the gas by turning the gas regulator to the on position The heater can be regulated to thre...

Page 13: ...r Attention Please do not forcefully turn the control knob the button should be pushed down before changing the heat control settings The control button will not turn without pushing downwards Ensure...

Page 14: ...erheating protection If the fan heater is too hot the heating element will not work You should disconnect the power code to wait for some minutes until the heater is cold then it could be restarted ag...

Page 15: ...tor switch on valve and the regulator disconnected from the cylinder Turn off the appliance from the container by means of the LPG container isolating valve 16 Only use in a well ventilated areas 17 T...

Page 16: ...ely dry before use 3 Don t use abrasive cleaners as they may damage the quality of paint nish MAINTENANCE 1 Check fexible tubing between regulator and heater regularly and replace If perished worn or...