GH05 GAS HEATER WITH TURBO
dcg16.it
21
Use only regulator and hose approved for LP Gas at the correct
pressures.
The pressure adjuster should comply with the standard EN12864 and
current regulations in the country where it is installed,which may be
found at your nearest retailer of gas items,Refer to the technical date.
It is strictly prohibited to use adjustable pressure.
The life expectancy of the regulator is estimated as 10 years.It is
recommended that the regulator is changed within 10 year of the
date of manufacture or the national conditions require it.
The type of replaceable hose should meet the standard of EN1763-1
Class 3.
The hose used must conform to the relevant standard for the country
of use.The length of the hose must be 0.5m (maximum).Worn
or damaged hose must be replaced.Ensure that the hose is not
obstructed,kinked,or in contact with any part of the appliance other
than at its connection.It is recommended that the hose is changed
within 1 year of the date of manufacture or the national conditions
require it.
How to choose proper regulator:
37 mbar regulator with butane,propane or their mixtures @ category
I3B/P(37)
30 mbar regulator with butane,propane or their mixtures @ category
I3B/P(30)
Warning
Perform a leak test on all connections every time you reconnect the
cylinder, or i
the heater has not used
or a signi
cant period.
Don’t twist the fexible tube or the hose.
Don’t move the appliance when lit
Summary of Contents for GH05