95
•
HOME SCREEN TIME OUT
[10s, 30s, 1min, 2min, 3min, 4min, 5min, 10min, DISABLED]
Sets the time that it takes for the VENU360 to return to the Home screen after a period of inactivity or disables the
Home Screen Time Out feature altogether.
NOTE:
Home Screen Time Out will not time out when in certain modes/menus. For instance, it will not time out
when in Configuration mode, any of the Wizards, the Preset Recall or Store menus, or the Utility menu. This prevents
the accidental loss of changes made by the user, such as when naming a preset.
•
PRESET POWERUP
[CURRENT, STORED]
Determines whether the VENU360 will boot with the settings it had when it was last powered down (CURRENT) or if it
will boot and reload the preset as it is stored in memory (STORED).
NOTE:
It takes ~5 seconds for a parameter change to be auto-saved when PRESET POWERUP is set to
CURRENT. If a parameter is changed and the VENU360 is immediately power cycled before the VENU360 has time
to auto-save it, the parameter change will not be retained after a power cycle.
•
MUTES POWERUP
[CURRENT, MUTE ALL]
Determines whether the VENU360 will boot with the output mute settings last used when the device was powered
down (CURRENT) or if it will always boot with all outputs muted (MUTE ALL).
•
NETWORK
Here you can configure DHCP, assign a static IP address, and set subnet mask and gateway settings for communication
with the control network. Use the on-screen instructions in each menu to adjust these network settings.
•
APP SECURITY
Select this option to edit your administrative password. The default password is ‘administrator’. Changing the password
to anything other than the default password will enable the App Security feature. When enabled, the VENU360 will
require a password before it can be controlled over a network using the VENU360 control app. Follow the on-screen
instructions to edit the password. Changing the password back to ‘administrator’ will disable the App Security feature.
•
DEVICE NAME
Allows you to change the name given to a VENU360 device. This is the name that appears for each VENU360 device
when viewed on the network using the VENU360 control app.
•
SALES BANNER
[OFF, ON]
Turns the Sales Banner on or off. The Sales Banner is used for display purposes only.
•
MAP NAVIGATION
[HORIZONTAL, VERTICAL]
Determines whether navigation moves vertically or horizontally when turning the SELECT wheel to navigate the
on-screen configuration map for selecting processing modules to edit or configure.
•
PRESET RECALL LIST
Sets the range of presets accessible from the front panel. By default, the PRESET RECALL LIST is set to allow access
to all 100 presets. Turning the SELECT wheel counter-clockwise will narrow the list of presets available for use. Turning
the SELECT wheel clockwise will expand the list of presets available for use. For example, if you use only the first
5 presets, you can narrow the list size to the first 5 presets to hide all others. The preset recall list size is selectable
from preset 1 up to 25, so when using this feature, make sure the presets you want access to reside in the lowermost
numbered preset memory locations. If required, presets at memory locations higher than 25 can be copied to lower
memory locations. See
for further information on copying presets.