97
System Lockout
This power-up function locks out the VENU360’s front panel controls to prevent unauthorized tampering. The available options
are:
•
Unlocked
This is the default setting and allows access to all VENU360 functions from the front-panel controls.
•
Locked
When this option is selected, all front-panel controls will be locked and a “LOCKED” message will appear in the LCD
display whenever any button is pressed or the SELECT wheel is turned.
•
Locked with AFS Clear
When this option is selected, all front-panel controls will be locked with the exception of the AFS Filter Clear function.
To clear the AFS filters when this option is selected, press the
EDIT
button, select the AFS module to clear using the
SELECT
wheel or
UP
/
DOWN
buttons, press the
SELECT
wheel to enter the AFS module, then press the
SELECT
wheel one more time to clear the filters.
•
Locked with AFS Clear and Mutes
This option is similar to the “System Locked with AFS Clear” option listed above. When this option is selected, all
front-panel controls will be locked with the exception of the AFS Filter Clear function and output mutes. To clear the
AFS filters when this option is selected, press the
EDIT
button, select the AFS module to clear using the
SELECT
wheel
or
UP
/
DOWN
buttons, press the
SELECT
wheel to enter the AFS module, then press the
SELECT
wheel one more
time to clear the filters.
TIP:
Before enabling any of the above “lockout with AFS clear” options, make sure to enter the AFS modules and set the
CLEAR MODE parameters to the desired setting. This will ensure the correct filter types can be cleared once the front panel
has been locked. See
‘Advanced Feedback Suppression (AFS) Module’ on page 62
editing the AFS CLEAR MODE parameter.
To change the System Lockout option:
1�
Press and hold the
RTA
button then power on the VENU360. Keep the button held until the System Lockout menu
prompt appears in the LCD display then release the button.
2�
Turn the
SELECT
wheel to highlight the desired option.
3�
Press the
SELECT
wheel to select the highlighted option.
4�
When prompted, press the
RTA
button to confirm the selection. The VENU360 will boot up and operate according to the
System Lockout option selected. Pressing any button other than the
RTA
button will abort the procedure and maintain
the setting selected prior to entering the System Lockout menu.