23
Dante Connections (VENU360-D)
When connecting a VENU360-D to other Dante devices,
one of the devices on the network must provide master
clock for all other connected devices. All configuration
settings for the Dante network, including master clock
device designation, must be configured using Audinate’s
Dante Controller sotware, available for free on Audinate’s
website. The only exception is the Clock Source setting,
which must be configured in the VENU360-D as shown
below.
VENU360-D Utility Settings:
Clock Source: Dante
NOTE:
In order for Dante audio to pass through the VENU360-D, the VENU360-D’s Clock Source setting must be set
to “Dante”. When this setting is selected, SRC will automatically be enabled on the AES inputs, allowing the AES and analog
inputs to be used alongside Dante inputs if required for the application.
VENU360 Inputs
(Optional)
(Optional)
Analog Device
Digital Device
w/ AES Outputs
Dante
Device