background image

3KP78 - 1.12

3000PLUS 

WITH 

5D78 I

NSTRUCTION 

M

ANUAL V

. SB.3

1.  I

NTRODUCTION

Modifying the Configurator 
Shortcut Target
(ONLY IF MICROSOFT
OFFICE 2003 IS INSTALLED)

13. To RUN the Configurator, go to your Windows

popup 

Start 

menu, select 

Programs

, and click

3000PLUS Configurator

.

PLEASE NOTE

IF

MICROSOFT OFFICE 2003

IS INSTALLED ON

YOUR COMPUTER, you will have to modify the “tar-
get” specification for the Configurator shortcut in
the 

Programs

list, as follows (you only need to do

this the first time you try to run the Configurator):

a.

RIGHT-CLICK on 

3000PLUS Configurator 

in

the 

Programs

list.

b.

Select 

Properties

.  The dialog box shown

below will appear, with the cursor at the
extreme right of the “Target” field.

c.

Press the 

LEFT ARROW

key (

) to move the

cursor to just after “Microsoft Office\Office.”

d.

Type “11” so that the target reads

“C:\Program Files\Microsoft Office\Office11\ . . .

e.

In the 

Start in

field, type “11” after “Microsoft

Office\Office” so that it reads

“C:\Program Files\Microsoft Office\Office11”

f.

Click 

OK

.

g.

Now you can run the Configurator by clicking
on 

3000PLUS Configurator

in the 

Programs

list.

THE CONFIGURATOR IS A MICROSOFT ACCESS
2000 RUNTIME PROGRAM.  DO NOT ATTEMPT TO
OPEN THE “5DCONF.MDE” FILE OR ANY CONFIG-
URATION “*.MDB” FILE DIRECTLY THROUGH
MICROSOFT ACCESS.

ALSO NOTE:

• If 

Microsoft Access 97

(or an older version) is

installed on your computer, the first time you
attempt to open an Access 97 (or older) file
after installing Access 2000 Runtime, you may
have to do so through the Access 97 program
itself.  That is, start Microsoft Access via the
Windows 

Start / Programs

menu, and use

Open an Existing Database... 

to open the file

in question.  Otherwise, the system may try to
open it as an Access 2000 file and ask if you
want to convert it, etc.  

•  After installing Access 2000 Runtime, you may

have to rejoin any workgroup to which you
were previously joined, using 

WRKGADM.exe

in the Windows System folder.

For proper viewing of the Configurator startup
page, your display should be set to at least 256 col-
ors.

(cont’d)

Summary of Contents for 3000PLUS

Page 1: ...d reproduced or used in any form or by any electronic mechanical or other means including photocopying and recording or in any information storage and retrieval system without permission in writing fr...

Page 2: ...has been properly installed If your 3000PLUS is equipped with a 5D Series conditioner model other than the 5D78 the corresponding instruction manu al should be consulted ALWAYS TURN OFF THE 3000PLUS B...

Page 3: ...ront Panel Setup Procedure 3KP78 3 4 4 SOFTWARE CONFIGURATION AND CALIBRATION 4 A Using the 3000Plus Configurator Software 3KP78 4 1 4 B Summary of Configurator Menus 3KP78 4 3 4 C Overview of OFF LIN...

Page 4: ...ain Gage Cabling under 20 ft in length 3KP78 2 3 Fig 8 b 8 Wire Strain Gage Cabling 20 ft or longer 3KP78 2 3 Fig 9 Analog Output Connections 3KP78 2 4 Fig 10 3000PLUS Logic I O Connections Fig 10 a L...

Page 5: ...plained in Sections 3 and 4 of this manual you can quickly set up the 3000PLUS either via the simple front panel button menu or via the configuration soft ware supplied with the unit Operator entered...

Page 6: ...nd power supply communi cations terminals 1 INTRODUCTION High ESD immunity and extensive EMI protec tion further assure data integrity in harsh industrial environments Because of normal cable loading...

Page 7: ...inal 0 5 V where 5 V Logic 1 AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA AAAAAAAAAAAAA A A A A 1 70 4 41 7 17 0 22 Fig 1 3000PLUS Dimensions true 25 V without damage noise im...

Page 8: ...d excitation frequency for an excitation of 10 00 kHz it is 2000 Hz for 5 00 kHz it is 1400 Hz and for 3 27 kHz it is 1100 Hz See Table 2 in Appendix B for the practical ranges that apply to the 5D78...

Page 9: ...ction 1 D Setup Indicators see Section 3 B Channel and Limit Value Indicators see Section 1 D Communi cations Indicator see Section 2 B Fig 2 3000PLUS Front Panel Elements Limit Logic Relay Outputs se...

Page 10: ...ser s Panel with Cutout and Mounting Holes see Fig 5 A B 4 060 3 700 0 180 0 200 0 156 dia Edge of 3000PLUS instrument 1 45 0 775 Fig 4 3000PLUS Panel Mounting Fig 5 Panel Cutout Dimensions 3 Remove t...

Page 11: ...setup or run time basis as explained in Section 4 The DECIMAL POINT RESOLUTION of the data display for Channels 1 and 2 will always match that of the last entered FSU value 2 You can also specify a DI...

Page 12: ...tification 2 RG RANGE input range and scaling information including for the 5D78 module excitation frequen cy full scale mV V range desired full scale reading in units and desired decimal point resolu...

Page 13: ...perator is called on to select one of a set of discrete values for a given setup parameter this button is used to cycle through the display of those values for details see Entering a Setup Parameter i...

Page 14: ...clears any currently captured peak value by momentarily disabling and re enabling peak capture see Section 5 B SETUP FUNCTIONS Used during setup to 1 Acknowledge each setup parameter when it appears...

Page 15: ...ut does require full installation of Microsoft Access 2000 Runtime which is supplied with the Configurator and which takes approximately 32 MB of hard drive space If Microsoft Office 2000 or higher is...

Page 16: ...Microsoft Office Office so that it reads C Program Files Microsoft Office Office11 f Click OK g Now you can run the Configurator by clicking on 3000PLUS Configurator in the Programs list THE CONFIGURA...

Page 17: ...want to completely remove the 3KP Configurator and all its components answer Yes to uninstall or No to abort You may be asked whether you re sure you want to remove MSCOMM32 OCX and COMDLG32 OCX which...

Page 18: ...r of the 3000PLUS instrument also shown in Fig 3 Each connected wire or jumper is to be firmly secured to the corresponding SCREW TERMINAL of the terminal block supplied with the meter that plugs into...

Page 19: ...nications between the 3000PLUS and an external PC While 3000PLUS PC serial com munications will usually take place through the 3KP Configurator software described in Section 4 a termi nal emulation pr...

Page 20: ...er 20 ft in length CAL SENSE SIGNAL CAL ENABLE EXCITATION SENSE SENSE EXCITATION SHIELD 10 9 8 7 6 5 4 3 2 1 SIGNAL EXTRA WIRE paired with CAL SENSE unconnected at Transducer Connector NOT ISOLATED co...

Reviews: