OPERATING CONDITIONS
Water Quality
:
Water outside the
following limits should be appropriately pre-
treated:
Direct: Clarity:
Clear
,
TDS:
<600mg/l,
Hardness:
<200mg/l CaCo ,
Saturation
3
Index
:
>0.8<1.0
Test Pressure
:
Tank - 5Bar, Collector
-10Bar
Max Operating Pressure
- 3.5Bar
3
Max Flow Rate
-
2m /hr
SPECIFICATIONS
Model
Typical Household (People)
Collector Model
UFD320DL
Max Heat Output/Day (kWhrs)
Collector Fluid Capacity (litres)
Min Heat Output/Day (kWhrs)
Collector Weight (kg)
3
Collector Area (m )
UFD160DS
UFD220DL
5
160
1.7
1.2
9
1 X FCP1.7
2 X FCP1.7
25
6
UFD160DL
2.4
1.5
14
1 X FCP2.4
2 X FCP2.4
38
10
UFD220DS
7
220
2.4
1.5
14
38
10
3.4
2.4
20
50
14
10
320
4.8
3.0
29
76
19
System Tank Size (Litres)
1 X FCP3.0
1 X FCP2.4
UFD320DS
3.0
1.7
18
48
12
A
B
C
D
E
Full Weight (kg)
Empty Weight (kg)
Dimensions (mm)
F
800
1920
2620
2780
700
253
93
600
800
1890
2590
2780
700
270
110
600
800
1890
2590
2780
700
355
135
600
1760
1920
2620
2780
700
376
156
600
800
2440
3140
2780
700
490
180
600
1760
1890
2590
2780
700
534
214
600
2
A
D
C
B
Inlet 3/4” BSP
Outlet 3/4” BSP
F
E
NOTE
1. Standard output systems (S Models) should be used in hot locations and
high output systems (L Models) in more temperate ones. However hot
water availability will vary throughout the year depending on prevailing
irradiation levels and electric boosters may be necessary on cooler days.
2. Maximum heating output is based on average irradiation levels of
2
6000W/m /day prevailing in September - March and minimum Heating
2
output is based on average irradiation levels of 4000W/m /dayprevailing
in June/July and are for indicative purposes only.
Summary of Contents for ULTRASUN UFD