25
F07.04
STOP/RESET
Key Stop
Function
Valid Mode
Function
Code
Name
Description
Modi-
ability
0
0~3
0: Only valid in panel run/stop control mode
1: Valid in panel and terminal run/stop
control modes
2: Valid in panel and communication
run/stop control modes
3: Valid in all run/stop control modes
Setting
Range
Default
Value
F07.05
Operation
State
Parameters
Display
Selection
BIT0: Operating frequency (light Hz on)
BIT1: Setting frequency (light Hz blinks)
BIT2: DC bus voltage (unit: 0.1 V, light V on)
BIT3: Output voltage (unit: 1 V, light V on)
BIT4: Output current (light A on)
BIT5: Rotation speed (lights Hz and % on)
BIT6: Output power (lights V and A on)
BIT7: Solar input voltage (unit: 0.1 V, light V
blinks)
BIT8~9: Reserved
BIT10: Input terminal state
BIT11: Output terminal state
BIT12~15: Reserved
0x00FF
0x00~
0xFFFF
F07.07
Stop State
Parameters
Display
Selection
BIT0: Setting frequency (light Hz on,
frequency blinks slowly)
BIT1: DC bus voltage (light V on)
BIT2: Input terminal state
BIT3: Output terminal state
BIT4: Solar input voltage
(light V blinks)
BIT5~6: Reserved
BIT7: Analog AIN value
(light V on)
BIT8~11: Reserved
BIT12: Pulse count value
BIT13~15: Reserved
0x001F
0x00~
0xFFFF
F07.11
Rectifier
Bridge
Module
Temperature
Unit:
℃
-
0~100.0
F07.12
IGBT Module
Temperature
Unit:
℃
-
0~100.0
F07.13
Software
Version
Current
Version
1.00~
655.35
F07.14
Accumulative
Operation
Time
Unit: Hour
-
0~65535
F07.15
Inverter
Power
Consumption
(high byte)
Unit: kWh (*1000)
-
0~65535