24
F05.01
Terminal DI1
Function
Function
Code
Name
Description
Modi-
ability
1
0~63
0: No function
1: Forward rotation operation 2~41:
Reserved
42: Disable solar inverter, force the inverter
to operate at power frequency (can be
used in AC/DC automatic s w i t c h i n g
function)
43: Tank full
44: Source low
45: Reserved
46~63:Reserved
Setting
Range
Default
Value
0x00~
0x1F
F05: Input Terminal Group
F05.02
Terminal DI2
Function
F05.03
Terminal DI3
Function
43
44
F05.04
Terminal DI4
Function
F05.05
Terminal DI5
Function
42
0
F05.10
Terminal DI1-
DI5 Function
BIT4~BIT0
DI5~DI1
0x04
F06: Output Terminal Group
F06.03
Relay T1
Output
Function
21
0~30
0: Invalid
1: In operation
2: In forward rotation
operation
3: In reverse rotation
operation
4: In jogging operation
5: Inverter fault
6~15: Reserved
16: Solar power supply
17: AC power supply
18~30: Reserved
5
F06.04
Relay T1
Output
Function
F06.05
Output
Terminal
Function
Enable Level
0x00~
0x03
0x00
BIT0
BIT1
T2
T1
F06.10
Relay T1
Close Delay
Time
Unit: second
0.000~
50.000
0.000s
F06.11
Relay T1
Open Delay
Time
Unit: second
0.000~
50.000
0.000s
F07: Human Machine Interface
F07.00
User
Password
0-65535
0~65535
0