Operation Panel Key Function
Key
Appearance
Name
Function Description
Enter or exit the first-level menu; Return to previous menu.
Programming Key
In variable display mode, left shift to circularly display different
variables such as frequency, speed, voltage, current, etc. In
parameter setting mode, left shift to select the bit to be modified; In
password authentication mode, left shift to select the bit to be
modified.
Shift Key (Left)
In operation panel run/stop control mode, RUN key is used to start
the inverter; In terminal run/stop control mode and when the
inverter has been manually stopped, RUN key is used to enable
start-up of the inverter; When RUN key and STOP/RESET key are
pressed at the same time, the inverter output will be stopped
instantly;
Run Key
Enter Key
In parameter setting mode, enter the menu progressively or
confirm parameters; In password authentication mode, confirm
the input password.
Shift Key (Right)
In variable display mode, right shift to circularly display different
variables such as frequency, speed, voltage, current, etc. In
parameter setting mode, right shift to select the bit to be modified;
In password authentication mode, right shift to select the bit to be
modified.
STOP/ RESET Key
STOP/RESET key is used for inverter stop control according to the
valid mode set in function parameter F07.04; When STOP/RESET
key and RUN key are pressed at the same time, the inverter output
will be stopped instantly; When a fault occurs and the inverter has
stopped, STOP/RESET key is used to reset the inverter and clear
fault alert.
Increment Key
Progressively increase the parameters or data.
Decrement Key
Progressively decrease the parameters or data.
4.2 Panel Operation Instruction
Parameter Modication
There is a three-level menu:
1. Group number of parameters (first level).
2. Serial number of parameters (second level).
3. Setting value of parameters (third level)