Indicator Lights
Label
Denition
Instruction
SYS
Pump
MPPT
ERR_I
LOW_POWER
Tank_F
WELL_L
System
Power
Pump running
Maximum
Power Point
Tracking
Current
Error
Voltage
Error
Tank Water
Level Alarm
Well Water
Level Alarm
Solar Mode: Indicator light is always on (not battery mode)
Battery Mode: Green indicator light blinking
Green indicator light will turn on after the pump starts running
Green light, monitor the power input from the solar arrays and adjust the
voltage and current to gain the highest performance from the pump
Red light is always on: Overload error
Red light blinking : Over current error :
Yellow light continuously on indicates the system voltage is too low
Green light, the tank is full
Green light, the well is empty
If the light is blinking, system is in time-delay mode
9
4.2.2 SunFlo-A
Pumps are controlled by an internal motor controller with no external monitoring or
adjustment provisions. However, pumps must be connected through the PV Isolator that
also provides over-current protection.
4.2.3 SunFlo-B
All SunFlo-B pumps are provided with an advanced MPPT controller that enhances pump
performance by up to 25%. The controller includes an isolator switch, protection from
over/under voltage, overcurrent, low level control (optional), indicator lights for pump
operating status and provision for high level floatswitch.