7
The connector wiring
must
meet the EIA/TIA 568 standart.
UTP / STP Connection Cable Wiring
The Local-Remote interconnection cable is terminated in RJ45 connectors and should
be wired according to the EIA/TIA 568 (Scheme B preferred) industry standard. The
Voyager will function with other wiring schemes, but the video quality may be
impaired.
Orientation: Looking into the RJ45 socket pin 1 is on the left and Pin 8 on the right.
Pin Wire Colour Wire Pair
1 White/Orange T2 2
2 Orange/White R2 2
3 White/Green
T3 3
4 Blue/White
R1 1
5 White/Blue
T1 1
6 Green/White
R3 3
7 White/Brown
T4 4
8 Brown/White
R4 4
The Voyager has been tested with all major makes of CAT 5 cable including BICC-
VERO, Mohawk, and Brand-Rex. The Voyager has also been tested with most major
makes of CAT 5E and CAT6 with good results.
Note:
That failure to wire the twisted pairs correctly will impair the video quality
dramatically and / or prevent correct operation.
This Voyager 100 extender is designed for use up to a maximum cable length of
100m/330ft At this length the video quality should still be acceptable even at a screen
resolution of 1200x1600 (75Hz).
Although a single continuous length of interconnect cable is preferable, operation is
possible through multiple Patch Panels. However, the more patch panels the cable is
routed through, the greater the chance of video signal degradation.
1 8