Read/Write Parameter Table
Modbus
Register
(Decimal)
Modbus
Register
(Hex)
Function
Code
(Read)
Function
Code
(Write)
No. of
Registers
Description
Range
Default Format Property Comment
270
10E
3
16
4
CURRENT_CONFIGURATION
hex
Read/WriteCheck the
section:
5.
Payload
for
downlink
message
for more
information
274
112
3
16
1
SERVER_CONFIG
uint16
Read/Write0: Send to
Sigfox
Network
1: Send to
Dongle
276
114
3
16
1
RADIO_CONFIG
1-4
4
uint16
Read/WriteRC zones
selection
1, 2 , 3, 4
is RC1,
RC2,
RC3s, RC4
277
115
3
16
1
TX_POWER
20
int16
Read/WriteRF Tx
power
278
116
3
16
2
CONSTANT_A
1
float
Read/WriteConstant a
for scaling
measured
value
280
118
3
16
2
CONSTANT_B
0
float
Read/WriteConstant b
for scaling
measured
value
282
11A
3
16
2
HIGH_CUT
1E+09
float
Read/WriteHigh cut
value for
the
calculated
value
284
11C
3
16
2
LOW_CUT
0,5
float
Read/WriteLow cut
value for
the
calculated
value
286
11E
3
16
2
SENSOR_BOOT_TIME
1000
uint32
Read/WriteBoot time
of
sensor/input,
in ms