14
E
3
1
SENSOR_TYPE
1-255
uint16
Read
Sensor or Input
Type
Read/Write Parameter Table
Modbus
Register
(Decimal)
Modbus
Register
(Hex)
Function
Code
(Read)
Function
Code
(Write)
No.
of
Registers
Description
Range DefaultFormatProperty
Comment
270
10E
3
16
4
CURRENT_CONFIGURATION
hex
Read/Write
Check the
section: 5.
Payload
for downlink
message
for more
information
274
112
3
16
1
SERVER_CONFIG
0
uint16 Read/Write
0: Send to Sigfox
Network
1: Send to Dongle
276
114
3
16
1
RADIO_CONFIG
1-4
4
uint16 Read/Write
RC zones selection
1, 2 , 3, 4 is RC1,
RC2, RC3s, RC4
277
115
3
16
1
TX_POWER
20
int16 Read/Write
RF Tx power
278
116
3
16
2
CONSTANT_A
1
float
Read/Write
Constant a for
scaling measured
value
306
132
3
16
1
ENB_DATGRAM
1
uint16 Read/Write
bit0: enable
datagram 0
bit1: enable
datagram 1
bit2: enable
datagram 2
307
133
3
16
1
TEMPERATURE_OFFSET_X10
0
int16 Read/Write
Offset adjustment
for measured
temperature value
Please refer to the detailed specifications in
3.3 Calibration for Sigfox-Ready V1A Vibration Sensor
4. Product specification
5. Warranty and Support