Technical data and handling
Light Therapie Units
LD 72, LD 110, LD
220, LD 440, LD 880 and LD 1100
DA
VIT
A
®
Medizinische Produkte GmbH & Co.
K
G
Postfach 2004,
D-47518
Kleve
www
.davita.de,
E-mail:
mail@da
vita.de
Instrument T
ype
:
Light Bo
x LD 72
Light Bo
x LD 1
1
0
P
h
ysioLight LD 220
Ph
ysioLight LD 440
Ph
ysioLight LD 880
Ph
ysioLight LD 1
1
0
0
Ar
ticle number:
1
0
072
1
0
11
0
1
0220
1
0440
1
0880
11
1
0
0
Medical product reg
arding
93/42/EWG
Y
e
s
Y
es
Y
e
s
Y
es
Y
e
s
Y
es
Simultaneous treatment of:
1 per
son
1 per
son
1 per
son
up to 2 per
sons
up to 3 per
sons
up to 4 per
sons
Housing:
High quality plastic housing
High quality stainless steel
Housing measures:
H: 61,
W
: 35, D: 1
1
,5 cm
H: 61,
W
: 35, D:1
1
,5 cm
H: 60,
W
: 40, D:8 cm
H: 66,
W
: 70, D:1
0
cm
H: 66,
W
:1
3
0, D: 1
0
c
m
H
: 66,
W
: 1
60, D:1
0
cm
W
eight:
3,4 k
g
3,9 k
g
7,
5 k
g
20 k
g
36 k
g
41 k
g
Lamps with a light spectrum
similar to the sunshine:
2 x 36 w
a
tt
s
2
x 55 w
a
tt
s
4
x 55 w
a
tt
s
8
x 55 w
a
tt
s
1
6 x 55 w
a
tt
s
20 x 55 w
a
tt
s
Lighting power
, distance
1
0.0
0
0
Lux at 20 cm
1
0.0
0
0
Lux at 30 cm
1
0.0
0
0
Lux at 50 cm
1
0.0
0
0
Lux at 65 (40*) cm
1
0.0
0
0
Lux at 65 (40*) cm
1
0.0
0
0
Lux at 65 (40*) cm
and therapy length:
distance for 30 minutes
distance for 30 minutes
distance f
o
r 30 minut
es
distance f
o
r 30 minut
es
distance f
or 30 minut
e
s
distance f
or 30 minut
e
s
Impor
tant:
Please notice
5.0
0
0
at 35 cm
5.0
0
0
Lux at 45 cm
5.0
0
0
Lux at 75 cm
5.0
0
0
Lux at 1
0
0 (70*) cm
5.0
0
0
Lux at 1
0
0 (70*) cm
5.0
0
0
Lux at 1
0
0 (70*) cm
that the light therapy can
distance for 60 minutes
distance f
o
r 60 minut
es
distance for 60 minutes
distance for 60 minutes
distance for 60 minutes
distance for 60 minutes
only successfully used in
a distance of at least
2.50
0 Lux at 55 cm
2.50
0 Lux at 70 cm
2.50
0 Lux at 1
0
0 cm
2.50
0 Lux at 1
50 (1
0
0*) cm
2.50
0 Lux at 1
50 (1
0
0
*) cm
2.50
0 Lux at 1
50 (1
0
0*) cm
45 - 55 cm!
distance f
or 2 hours
distance for 2 hour
s
d
istance for 2 hour
s
d
istance for 2 hour
s
d
istance for 2 hour
s
distance for 2 hour
s
A
verage lifetime of the
lamps reg
arding the
appro
x. 1
0.0
0
0
hour
s
appro
x. 1
0.0
0
0
hour
s
appro
x. 1
0.0
0
0
hour
s
appro
x. 1
0.0
0
0
hour
s
appro
x. 1
0.0
0
0
hour
s
appro
x.
1
0.0
0
0
hour
s
specification of the producer:
Energy costs:
(at an average price
< 0,02
€
per hour
< 0,02
€
per hour
appro
x. 0,02
€
per hour
appro
x. 0,04
€
per hour
appro
x. 0,08
€
per hour
appro
x. 0,1
0
€
per hour
v
on 0,1
2
€
/ kWh:
Degree of protection:
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
Class of protection:
I
I
I
I
I
I
Degree of protection:
B
B
B
B
B
B
Medical device:
class II a
class II a
class II a
class II a
class II a
class II a
F
use:
1 F
use
1 F
use
2 F
u
se
2 F
u
se
2 F
use
2 F
u
se
5 x 20 /
T 1A L 250V
5 x 20 /
T 2A H 250V
5 x 20 /
T 2A H 250V
5 x 20 /
T 3,1
5A H 250V
5 x 20 /
T 5A H 250V
5 x 20 /
T 6,3A H 250V
T
imer:
Not available
Not available
The units have a timer for stepless preset
ting of the therapy duration between 0 and 1
2
0 minute
s.
Electric ballast units:
Instant star
ting, flicerfree light, no stroboscopic ef
fect. Buzz free operation.
Automatic switc
h of
f at the end of lamp li
ve t
ime.
Light emission:
The selection of lighting source and light filter reduces the energy of light emit
ted in the Infrared and UV ran
ge to a minimum level, so it is harmless to human skin and eyes.
Storage:
- 1
0
degrees C up to 50 degrees C and a relati
ve humidity of max. 90 %
Mains requirements:
230 – 240
V~, 50 – 60 Hz
*Reg
ar
ding the LD 440 - LD 1
1
0
0
the v
a
lues in br
ac
k
ets ar
e r
eac
hed b
y
position 1 of the t
u
rning knob.
In this position only ev
ery second lamp illuminat
es.
T
e
chnical c
hanges can be applied at an
y time without prior notice.
01
2