Page 8 of 52
"BARDATA"
Displays of the current barometer calibration parameters in text.
6.
Clearing Commands
"CLRLOG"
Clears the archive data.
"CLRALM"
Clears all the alarm thresholds.
"CLRCAL"
Clears all the Temperature and Humidity calibration offsets.
"CLRGRA"
Clears all of the graph points on the Vantage console.
"CLRVAR <Data variable-decimal>"
Clears a rain or ET data value.
"CLRHIGHS <0, 1, or 2>"
Clears all of the daily (0), monthly (1), or yearly (2) high values.
"CLRLOWS <0, 1, or 2>"
Clears all of the daily (0), monthly (1), or yearly (2) low values.
"CLRBITS"
Clears the active alarm bits. Alarms will be reactivated if the alarm condition is still present.
"CLRDATA"
Clears all current data values to dashes.
7.
Configuration Commands
"BAUD <New baud rate-decimal>"
Sets the console to a new baud rate.
Valid values are 1200, 2400, 4800, 9600, 14400, and 19200.
"SETTIME"
Sets the time and date on the Vantage console. Data in a binary format is sent after ACK.
"GAIN <Gain State: '0' (off) or '1' (on)>"
Sets the gain of the radio receiver. This command is currently not supported in Vantage Pro2.
"GETTIME"
Retrieves the current time and date on the Vantage console. Data is sent in a binary format.
"SETPER <Archive interval in minutes-decimal>"
Sets the Vantage archive interval. Valid values are (1, 5, 10, 15, 30, 60, and 120).
"STOP"
Disables the creation of archive records.
"START"
Enables the creation of archive records, if they have been halted with the STOP command.
"NEWSETUP"
Re-initialize the Vantage console after making certain configuration changes.
"LAMPS <Lamp state: '0' (off) or '1' (on)>"
Turns the lamps on the Vantage console on or off.
VIII.
Command Details
All commands must be terminated by a single line feed character (‘\n’) or a single carriage return
character (‘\r’). These are not shown in the command syntax, but are shown in the examples.