EEPROM address table
Name Hex
Dec
Size Description
BAR_GAIN 1
1
2
BAR_OFFSET 3
3
2
These are the factory barometer calibration values.
Do not modify them!
BAR_CAL
5
5
2
Barometer Offset calibration.
Use the
"BAR="
command to set this value!
HUM33 7
7
2
HUM80 9
9
2
These are the factory inside humidity calibration values.
Do not modify them!
LATITUDE
0B
11
2
Station Latitude in tenths of a degree. Negative values =
southern hemisphere
LONGITUDE
0D
13
2
Station Longitude in tenths of a degree. Negative values =
western hemisphere
ELEVATION
0F
15
2
Station elevation in feet.
Use the
"BAR="
command to set this value!
TIME_ZONE
11
17
1
String number of the time zone selected on the setup
screen.
MANUAL_OR_AUTO
12
18
1
1 = manual daylight savings, 0 = automatic daylight
savings
DAYLIGHT_SAVINGS
13
19
1
This is the configuration bit for the day light savings mode
when it is set in manual mode. 1 = daylight savings is now
on, 0 = daylight savings is now off. When automatic
daylight savings mode is selected, this bit is ignored and it
does not indicate whether the daylight savings is on or not.
GMT_OFFSET
14
20
2
The time difference between GMT and local time (a 2-byte
signed number in hundredths of hours. For example, a
value of 850 would be +8.50 hours. Negative values in
2’s complements, represent western hemisphere.
GMT_OR_ZONE
16
22
1
1 = use the GMT_OFFSET value, 0 = use the TIME_ZONE
value
USETX
17
23
1
Bitmapped field that indicates which DavisTalk
transmitters to listen to. Bit 0 = ID 1.
RE_TRANSMIT_TX
18
24
1
ID number to use for retransmit. 0 = don't retransmit, 1 =
use ID 1.
STATION_LIST
19
25
16 2 bytes per transmitter ID. First byte is station type, second
byte is <temp sensor # | hum sensor #>. See section XIII.4
for more details.