5.1 Adjustable Speed Mode (SPVSB)
In the adjustable speed mode the UP and DOWN buttons are used to set the blower to one of 9 dif-
ferent speeds. On the first press of UP or DOWN the LCD will display “BLOWER SPEED” along with
a bar graph showing the current speed setting. While viewing this display you may press the UP and
DOWN button to adjust the speed as required. Hold down either button for automatic key press repeat.
This setting is saved and will be automatically restored next time you select the adjustable speed mode.
Notes:
1. The UP and DOWN buttons are shared with Light Level, Light Mode, SPVSB speed and the menu
system. When not within the menu system the actual use of the UP and DOWN buttons depends
on which of the three function buttons was pressed last - Light Level, Light Mode or Air.
2. Pressing the Air button while the blower is running will only cycle through the available options
when the LCD is displaying the current selection. This allows the first push of the Air button to set
the function of the UP and DOWN buttons and to show the current Blower setting without changing it.
3. Pressing either the UP or DOWN button while in the full-speed or oscillating mode will automatically
change the SPVSB to adjustable speed mode.
4. If left on, this accessory will automatically switch off after 25 minutes.
5. If the heater element is on, switching on the SPVSB may cause the heater to load shed and switch off.
If this occurs the heater will come back on approximately 5 seconds after the SPVSB is turned off.
6 Spa Power Variable Colour Light (SPVCL)
The Spa Power Variable Colour Light is controlled via two touch pad buttons - Light Level and Light
Effect Mode. If no SPVCL is fitted then the buttons can still be used to produce lighting effects on the
touch pad as though a light was fitted.
The Light Level button selects the intensity of the light and the Light Effect Mode button selects the
light colour and effect.
Five pushes of the Light level button selects the light intensity as follows:
Push 1 (High)
LCD Displays “LIGHT HIGH”, 100% light intensity
Push 2 (Medium)
LCD Displays “LIGHT MEDIUM”, 66% light intensity
Push 3 (Low)
LCD Displays “LIGHT LOW”, 33% light intensity
Push 4 (Adjust)
LCD Displays “LIGHT ADJUST”, adjustable light intensity
mode, button LED colour changes with setting when up or
down buttons are pressed.
(Green 2-32, Orange 34-66, Red 68-100%)
Push 5 (Off)
LCD Displays “LIGHT OFF”, light off
Pressing the UP or DOWN button while in high, medium or low mode will automatically change to
adjustable mode.