background image

 

 
 
 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

Davey Water Products Pty Ltd 
Member  of  the  GUD  Group 
ABN 18 066 327 517

 

 

AUSTRALIA

 

Head Office

 

6 Lakeview Drive,

 

Scoresby, Australia 3179

 

Ph: 

1300 232 839

 

Fax:         1300 369 119

 

Email: 

[email protected] 

Website:  davey.com.au

 

INTERNATIONAL

 

Australian Head Office

 

Ph: 

+613 9730 9124

 

Fax: 

+613 9753 4248

 

Email: 

[email protected] 

Website:  davey.com.au

 

 
 

 

EUROPE

 

ZAC des Gaulnes

 

355 Avenue Henri Schneider 

69330 Meyzieu, France

 

Ph: 

+33 (0) 4 72 13 95 07

 

Fax: 

+33 (0) 4 72 33 64 57

 

Email: 

[email protected] 

Website:  daveyeurope.eu

 

NEW ZEALAND

 

7 Rockridge Avenue,

 

Penrose, Auckland 1061

 

Ph: 

0800 654 333

 

Fax: 

0800 654 334

 

Email: 

[email protected] 

Website:  daveynz.co.nz

 

NORTH AMERICA

 

Ph: 

+1 866 328 7867

 

Email: 

[email protected] 

Website:  daveyusa.com

 

MIDDLE EAST

 

Ph: 

+971 50 6368764

 

Fax: 

+971 6 5730472

 

Email: 

[email protected] 

Website:  daveyuae.com

 

 

® Davey is a trademark of Davey Water Products Pty Ltd.  © Davey Water Products Pty Ltd 2018. 

P/N 403277

 

Summary of Contents for SILENSOR PRO SP200BTP

Page 1: ...ause serious bodily injury and or property damage This pump requires professional expertise for installation and maintenance The installation of this product should be carried out by a person knowledg...

Page 2: ...ey should not be used for any other purpose without first consulting your Davey Dealer or the Davey Customer Service Centre Every Davey SilensorPro is thoroughly water tested against a number of flow...

Page 3: ...are used to This is also NORMAL The lower system pressure is simply a result of the lower speed and flow rate produced by the pump While running at the lower speed settings you will also notice a sig...

Page 4: ...The unit must be connected only to a supply circuit that is protected by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basi...

Page 5: ...r Recommended Pump Operating Hours Australian Standards AS3633 Private swimming pools water quality states that The minimum turnover rate shall be a single turnover of the full volume of the pool wate...

Page 6: ...cated by the gauge on the media or cartridge filter Ensure flow rate is sufficient to cover your chlorinator cell plates completely at all times of operation Technical Specifications Model SP200BTP He...

Page 7: ...pump should be located as close to the water as practicable and mounted on a firm base in a well drained position high enough to prevent any flooding It is the installer s owner s responsibility to lo...

Page 8: ...s on this product are constructed of ABS Some PVC jointing compounds are incompatible with ABS Check compound suitability before use Warning Ensure that an electrical isolation switch is located with...

Page 9: ...pumps speed dial The use of any pipe smaller than those specified above is not recommended Suction piping should be free from all air leaks and any humps and hollows which cause suction difficulties...

Page 10: ...c The pump enclosure has adequate drainage in the event of leakage c Any transport plugs are removed c The pipe work is correctly sealed and supported c The pump is filled with water to the inlet c Th...

Page 11: ...st speed and therefore the greatest energy efficiency and savings See table below for all other dial positionspeeds and functions Operation Recommended Speed Setting Pool Filtration Speed 1 to 4 Sucti...

Page 12: ...12 SP200BTP Performance...

Page 13: ...cooled design for smooth and super quiet operation The pump has a water cooled membrane and jacket around the motor which helps to keep the pump cool during operation Waste heat off the motor is trans...

Page 14: ...s or m3 hr Pairing a device to the pump 1 Open app 2 Turn dial on the pump from off to Bluetooth you will see the LED flash white for a second 3 Press the scan button 4 When setting up for the first t...

Page 15: ...ne is not in range Anytime the dial is switched to the Bluetooth position it will run at the previous set speed after the priming cycle Schedule Mode Schedule mode allows you to set the pump speed by...

Page 16: ...device and the pump can take up to 20 secondsdepending on the schedule selected Note The row at the bottom of the screen indicates a summary of where the schedule is by day and by hour This summary s...

Page 17: ...External Timer Present Swipe this on or off depending on whether you are using an external timer chlorinator Disconnect Function The disconnect from pump function can be used to 1 Allow another device...

Page 18: ...lug for 1 minute and plug back in to reset if problem persists contact your nearest dealer Pump Fault EEPROM Checksum Unplug for 1 minute and plug back in to reset if problem persists contact your nea...

Page 19: ...er Speed 3 to 7 should be ample for most cleaners however if the cleaner requires better performance select speeds 7 to 10 4 The cleaner should only be connected for as long as is required to clean th...

Page 20: ...he following condition may apply 1 The filter requires backwashing or it is blocked Refer to the relevant section in the Filter Manual 2 The pump is not primed Re prime as per instruction in Starting...

Page 21: ...the power source NOTE If the pump is wired into a time clock or another automatic control the wiring should be removed by a qualified technician 2 Close the water valves on the pool return and the pu...

Page 22: ...NOTES...

Page 23: ...NOTES...

Page 24: ...ulnes 355 Avenue Henri Schneider 69330 Meyzieu France Ph 33 0 4 72 13 95 07 Fax 33 0 4 72 33 64 57 Email info daveyeurope eu Website daveyeurope eu NEW ZEALAND 7 Rockridge Avenue Penrose Auckland 1061...