8
Davey Water Products recommends that all installations are
fitted with earth leakage or residual current protection devices.
CAUTION: In the interest of safety, we advise that all brands
and types of pool pumps must be installed in accordance with
AS3000 wiring rules or equivalent.
If the pump and filter are located below pool water level, it is
necessary to fit isolating valves in the pipe between the pump
and skimmer box and in return pipe from the filter to the pool.
The fittings on this product are constructed of ABS. Some PVC
jointing compounds are incompatible with ABS. Check
compound suitability before use.
Warning! Ensure that an electrical isolation switch is located
with easy access so that the pump can be switched off in an
emergency.
Heat Pump Connection
The SilensorPro VSD pump can be connected to a heat pump via a simple
two-wire connection, see Figure 1. If your heat pump has the capability to
output a signal when it has turned on, then the pump can use the signal to set
the speed of the pump to a maximum. This maximises the efficiency of your
heat pump to ensure maximum power savings. Dip switch 1 must be set
correctly as per Figure 1.
Figure 1