FUEL PRO
®
485
TECHNICAL MANUAL
®
F1485 REV B
T e c h n o l o g y , L L C
7
DAVCO Technology, LLC
www.davco.com
800-328-2611
1600 Woodland Drive, Saline, MI 48176-1629
Pre-heater Wiring with Relay
85
30/51
87
86
12/24 VDC
OPTIONAL
RELAY
+
-
Heater
Pre-heater Fuse
Harness
Connector
Ignition
Circuit
Fuse
87A
87
86
85
30/51
The 12VDC or 24VDC electric pre-heater is installed in the
pre-heater port on the side of the Fuel Pro .
1 . Open the vent cap . Open the drain valve by turning one to
one and a half revolutions . Drain the Fuel Pro completely .
Close the drain valve .
2 . Remove the pipe plug in the heater port .
3 . Apply liquid thread sealant to the pre-heater threads and
install into the bottom plate . Tighten to 15-30 ft-lbs .
4 . Connect the chassis harness to the Fuel Pro harness .
5 . Connect the power lead to the fused accessory side of
the ignition switch . The fuse rating depends on the pre-
heater installed .
6 . Prime the Fuel Pro and check for leaks .
Approved fuse ratings
•
12VDC System:
-
20 amp fuse for a 155W PTC heater
-
25 amp fuse for a 195W PTC heater
•
24VDC System:
-
15 amp fuse for a 195W PTC heater
If the keyed circuit will not handle the required amperage for
the pre-heater, use a relay .
Pre-heater Port
12VDC/24VDC PRE-HEATER INSTALLATION