background image

PureWay Compliance, Inc. 

20501 Katy Freeway Suite 206
Katy, TX 77450

877.765.3030

www.PureWay.com

ECO II

AMALGAM

SEPARATOR

EQUIPMENT LOGBOOK

ASSEMBLY, OPERATION  

   AND MAINTENANCE

Summary of Contents for ECO II

Page 1: ...PureWay Compliance Inc 20501 Katy Freeway Suite 206 Katy TX 77450 877 765 3030 www PureWay com ECO II AMALGAM SEPARATOR EQUIPMENT LOGBOOK ASSEMBLY OPERATION AND MAINTENANCE ...

Page 2: ...ly Yes No Was the system needing to be replaced Yes No MONTH 5 Name of the person who inspected Date of Inspection Was the system operating properly Yes No Was the system needing to be replaced Yes No MONTH 6 Name of the person who inspected Date of Inspection Was the system operating properly Yes No Was the system needing to be replaced Yes No MONTH 7 Name of the person who inspected Date of Insp...

Page 3: ...Explanation of how the system works 4 ECO II Application and explanation of the type plate 5 ECO II Assembly Instructions 6 ECO II Installation Guide 8 ECO II Tandem 10 Maintenance and Replacing the collection container 11 Disposal of the full collection container 13 Contact Us 14 ...

Page 4: ...rst sedimentation cartridge 3 3 through cascades 3 4 and the second sedimentation cartridge 3 5 into the second sedimentation chamber 3 6 Through the third sedimentation cartridge 3 7 the cleaned water is led directly into the sewage pipe 3 8 In wet ring systems the clean water is led into the wet ring pump Technical Data Low pressure range 50mbar 300mbar Separation rate 99 in accordance with ISO ...

Page 5: ...e Vacuum Systems dry vacuum system with air water seperation wet ring systems The type plate is located directly on the front side of the amalgam separator The type plate is located directly on the front side of the amalgam separator 2 1 Equipment type 2 2 Serial number 2 3 Manufacturer s address 2 4 Distributor s address 2 5 Max suction volume 2 6 Max water flow rate Type Plate 2 5 2 6 2 1 2 2 2 3...

Page 6: ... II Two stainless steel cylinders Remove all contents from the ECO II Each system comes with the following components Secure the black foundation brackets by placing bracket 1 on top of bracket two as shown below ensuring the brackets fit securely into the alignment grooves Bracket 1 Bracket 2 Bracket 1 placed on top of bracket 2 The ECO II Amalgam Separator requires minor assembly before ready to...

Page 7: ...nt Fit the stainless steel cylinders onto the two canister base support as shown in the illustration below Then fit the ECO II canister on top of the base support cylinders and then secure with the small screws Identify the appropriate fittings you plan on using during installation and fit the O rings on to the applicable fittings as shown below You are now ready to start the installation STEP 3 S...

Page 8: ...Tandem are installed in the vacuum line before the wet ring pump If you would like your ECO II to be mounted on a wall you must request these wall mounts at 877 765 3030 or go to www PureWay com contact page and request Optional Wall Bracket Installation Installation Options of ECO II The stainless steel wall mounts are affixed to a wall using screws provided Stainless steel rectangular wall mount...

Page 9: ...from air water seperator 10 2 Waste water outlet cleaned waste water directly to the sewage pipe Filling level As soon as the solid content of the collection container has reached the maximum flling level the ECO II must be replaced However it has to be replaced at least once a year even if the maximum flling level has not yet been reached Installation with a dry vacuum system The ECO II ECO II Ta...

Page 10: ...stallation Instructions IN In order to connect the ECO II in tandem configuration take two ECO II systems and connect them using a Y Connector as shown in the illustrations below 10 PureWay STEP 1 STEP 3 STEP 2 OUT IN ...

Page 11: ...ment interval table cf page 8 chapter 6 Remove the adapter with the tube at the waste water inlet and waste water outlet Detach the screws from the bolts 3 1 and take out the full amalgam separator by lifting it off upwards Tightly close the outlet of the full ECO II with the sealing plug supplied with the amalgam separator Position the full amalgam separator horizontally onto an even surface make...

Page 12: ...are found check the hose connections Install the new amalgam separator and secure it with the bolts and screws Reconnect the adapter with the tube to the IN and OUT openings Put the amalgam separator into the plastic liner supplied with the new amalgam separator place it into the styrofoam shells and then into the carboard box Afterwards also tightly close the inlet opening with the sealing plug ...

Page 13: ...stalling your ECO II Call 877 765 3030 and PureWay can assist you in finding a qualified technician to install your system To access your e certificates online and to sign up to receive your e certificates via e mail please visit www PureWay com Wear protective gloves and face mask Avoid contact with the contents of the container Disposal of the full collection container Put the amalgam separator ...

Page 14: ...ECO II AMALGAM SEPARATOR Contact Us PureWay Compliance Inc 20501 Katy Freeway Suite 206 Katy TX 77450 877 765 3030 www PureWay com ...

Reviews: