3: Operation
RT7000-MSOP
3-15
(18) LQA EXCNG
For requesting that a calling or called station exchange
a measurement of the link quality received on the other
end. Enter
1
for
OFF
(no request) and
2
for
ON
(yes
request), or use the arrows to toggle between
OFF
and
ON
.
(19) LQA DECAY
For entering the time period in which an LQA memory
cell linearly decays from a state of perfect (30) to a
state of dead (0). Selectable in periods of 0, 1, 2, 4 or 8
hours.
(20) BER THRSD
For entering the acceptable bit error rate threshold (00-
48) for received ALE words. A threshold of 00 allows
for no errors, while a threshold of 48 is the maximum
amount of allowable errors. The factory default is set to
48 allowable errors.
(21) GOLAY THD
For controlling the error correcting capability threshold
(0-4). A value of 0 allows for no corrections while a
value of 4 is the maximum amount of corrections
allowable. The factory default is set to 3 allowable
errors.
(22) ERR THRSD
For controlling the number of errors allowed before a
word is rejected (0-4). A value of 0 allows for no errors
while a value of 4 is the maximum amount of errors
allowable. The factory default is set to 3 allowable
errors.
(23) MESSG OUT
For assigning a number to an outgoing message (from 0
to 9). Enter a new assigned number or an existing num-
ber to review or change. To enter a new or different
message, use
(24) NEW MESSG
.
(24) NEW MESSG
For creating a new outgoing message for the number
assigned in
(23) MESSG OUT
. Any existing message
is briefly displayed. Use the alpha characters on the
keypad to create a new message up to 90 characters.
(25) MESSG IN
For selecting an incoming message for review (from 0
to 9). Messages are deleted when a tenth message is
received.
(26) HANDSHAKE
For setting the message exchange compatibility with
other radios. Enter
1
for
NO Tx,
or
2
for
NO Rx
.