3: Operation
3-24
RT7000-MSOP
TransAdapt
The RT7000 can be on a fixed channel or in scan mode. On a fixed channel,
TransAdapt operates the same as Selcall. In scan mode, TransAdapt locates
the first usable frequency, not the best.
1. Turn the
FUNCTION
knob until the
TA
icon flashes.
2. Press
STATUS
to turn the option
ON
.
3. Press
SCAN
.
4. Press
CALL/SEND
to initiate the call.
5. Enter the code of the transceiver to call (001 to 255). A call to all
channels (Allcall) is code 000.
6. Press
CALL/SEND
again. The RT7000 is now under full control of the
TransAdapt circuit.
The RT7000 starts transmission on each of the ten channels until it is
synchronized with the station called.
Display:
TA LINK
If the call is unsuccessful, calling discontinues and
NO
LINK
is briefly
displayed.
7. To break the connection, press
SCAN
.
8. To stop the call before connecting, press
CALL/SEND
.
Activating the Noise Blanker
The Noise Blanker option (7000NB) eliminates impulse-type interference in
high-noise environments.
1. Turn the
FUNCTION
knob until the
NB
icon flashes.
2. Press
STATUS
to turn the option
ON
.
Activating Encryption
This Encryption option (7000ENCR) provides high-level security.
1. Turn the
FUNCTION
knob until the
ENCR
icon flashes.
2. Press
STATUS
to toggle between
1
and
OFF
. The
1
position turns the
7000ENCR on.
For more detailed information on this security option, refer to the 7000-Series
High-Level Encryption operator manual (7000ENCR-MSOP).